Stable Isotope Labeling Tandem Mass Spectrometry (SILT): Integration with Peptide Identification and Extension to Data-Dependent Scans
- 6 September 2008
- journal article
- research article
- Published by American Chemical Society (ACS) in Journal of Proteome Research
- Vol. 7 (10) , 4546-4556
Abstract
Quantitation of relative or absolute amounts of proteins by mass spectrometry can be prone to large errors. The use of MS/MS ion intensities and stable isotope labeling, which we term stable isotope labeling tandem mass spectrometry (SILT), decreases the effects of contamination from unrelated compounds. We present a software package (SILTmass) that automates protein identification and quantification by the SILT method. SILTmass has the ability to analyze the kinetics of protein turnover, in addition to relative and absolute protein quantitation. Instead of extracting chromatograms to find elution peaks, SILTmass uses only scans in which a peptide is identified and that meet an ion intensity threshold. Using only scans with identified peptides, the accuracy and precision of SILT is shown to be superior to precursor ion intensities, particularly at high or low dilutions of the isotope labeled compounds or with low amounts of protein. Using example scans, we demonstrate likely reasons for the improvements in quantitation by SILT. The appropriate use of variable modifications in peptide identification is described for measurement of protein turnover kinetics. The combination of identification with SILT facilitates quantitation without peak detection and helps to ensure the appropriate use of variable modifications for kinetics experiments.Keywords
This publication has 39 references indexed in Scilit:
- A quantitative analysis software tool for mass spectrometry–based proteomicsNature Methods, 2008
- Mass spectrometric mapping of fibrinogen conformations at poly(ethylene terephthalate) interfacesBiomaterials, 2007
- Integrated Pipeline for Mass Spectrometry-Based Discovery and Confirmation of Biomarkers Demonstrated in a Mouse Model of Breast CancerJournal of Proteome Research, 2007
- Stable isotope labeling tandem mass spectrometry (SILT) to quantify protein production and clearance ratesJournal of the American Society for Mass Spectrometry, 2007
- Human amyloid-β synthesis and clearance rates as measured in cerebrospinal fluid in vivoNature Medicine, 2006
- Production and characterization of astrocyte-derived human apolipoprotein E isoforms from immortalized astrocytes and their interactions with amyloid-βNeurobiology of Disease, 2005
- Multiplexed Protein Quantitation in Saccharomyces cerevisiae Using Amine-reactive Isobaric Tagging ReagentsMolecular & Cellular Proteomics, 2004
- Selective Detection of Membrane Proteins Without AntibodiesMolecular & Cellular Proteomics, 2002
- Probability-based protein identification by searching sequence databases using mass spectrometry dataElectrophoresis, 1999
- An approach to correlate tandem mass spectral data of peptides with amino acid sequences in a protein databaseJournal of the American Society for Mass Spectrometry, 1994