Using Nonequilibrium Capillary Electrophoresis of Equilibrium Mixtures (NECEEM) for Simultaneous Determination of Concentration and Equilibrium Constant
- 10 February 2015
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 87 (5) , 3099-3106
Abstract
Nonequilibrium capillary electrophoresis of equilibrium mixtures (NECEEM) is a versatile tool for studying affinity binding. Here we describe a NECEEM-based approach for simultaneous determination of both the equilibrium constant, Kd, and the unknown concentration of a binder that we call a target, T. In essence, NECEEM is used to measure the unbound equilibrium fraction, R, for the binder with a known concentration that we call a ligand, L. The first set of experiments is performed at varying concentrations of T, prepared by serial dilution of the stock solution, but at a constant concentration of L, which is as low as its reliable quantitation allows. The value of R is plotted as a function of the dilution coefficient, and dilution corresponding to R = 0.5 is determined. This dilution of T is used in the second set of experiments in which the concentration of T is fixed but the concentration of L is varied. The experimental dependence of R on the concentration of L is fitted with a function describing their theoretical dependence. Both Kd and the concentration of T are used as fitting parameters, and their sought values are determined as the ones that generate the best fit. We have fully validated this approach in silico by using computer-simulated NECEEM electropherograms and then applied it to experimental determination of the unknown concentration of MutS protein and Kd of its interactions with a DNA aptamer. The general approach described here is applicable not only to NECEEM but also to any other method that can determine a fraction of unbound molecules at equilibrium.Keywords
Funding Information
- Natural Sciences and Engineering Research Council of Canada (238990)
This publication has 16 references indexed in Scilit:
- On the binding affinity of macromolecular interactions: daring to ask why proteins interactJournal of The Royal Society Interface, 2013
- Method for Determination of Peak Areas in Nonequilibrium Capillary Electrophoresis of Equilibrium MixturesAnalytical Chemistry, 2011
- Selection of aptamers for a non-DNA binding protein in the context of cell lysateAnalytica Chimica Acta, 2010
- Smart Aptamers Facilitate Multi-Probe Affinity Analysis of Proteins with Ultra-Wide Dynamic Range of Measured ConcentrationsJournal of the American Chemical Society, 2007
- Kinetic CE: Foundation for homogeneous kinetic affinity methodsElectrophoresis, 2007
- Aptamer-Based Detection and Quantitative Analysis of Ricin Using Affinity Probe Capillary ElectrophoresisAnalytical Chemistry, 2006
- Selection of Smart Aptamers by Methods of Kinetic Capillary ElectrophoresisAnalytical Chemistry, 2006
- Nonequilibrium Capillary Electrophoresis of Equilibrium Mixtures (NECEEM): A Novel Method for Biomolecular ScreeningSLAS Discovery, 2006
- Selection of Smart Aptamers by Equilibrium Capillary Electrophoresis of Equilibrium Mixtures (ECEEM)Journal of the American Chemical Society, 2005
- Instrumentation for Chemical CytometryAnalytical Chemistry, 2000