Ideal current patterns yielding optimal signal‐to‐noise ratio and specific absorption rate in magnetic resonance imaging: Computational methods and physical insights
Open Access
- 29 November 2011
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 68 (1) , 286-304
Abstract
At high and ultra‐high magnetic field strengths, understanding interactions between tissues and the electromagnetic fields generated by radiofrequency coils becomes crucial for safe and effective coil design as well as for insight into limits of performance. In this work, we present a rigorous electrodynamic modeling framework, using dyadic Green's functions, to derive the electromagnetic field in homogeneous spherical and cylindrical samples resulting from arbitrary surface currents in the presence or absence of a surrounding radiofrequency shield. We show how to calculate ideal current patterns that result in the highest possible signal‐to‐noise ratio (ultimate intrinsic signal‐to‐noise ratio) or the lowest possible radiofrequency power deposition (ultimate intrinsic specific absorption rate) compatible with electrodynamic principles. We identify familiar coil designs within optimal current patterns at low to moderate field strength, thereby establishing and explaining graphically the near‐optimality of traditional surface and volume quadrature designs. We also document the emergence of less familiar patterns, e.g., involving substantial electric‐ as well as magnetic‐dipole contributions, at high field strength. Performance comparisons with particular coil array configurations demonstrate that optimal performance may be approached with finite arrays if ideal current patterns are used as a guide for coil design. Magn Reson Med, 2012.Keywords
This publication has 28 references indexed in Scilit:
- Electrodynamic constraints on homogeneity and radiofrequency power deposition in multiple coil excitationsMagnetic Resonance in Medicine, 2009
- Optimized quadrature surface coil designsMagnetic Resonance Materials in Physics, Biology and Medicine, 2007
- Efficient high‐frequency body coil for high‐field MRIMagnetic Resonance in Medicine, 2004
- Parallel excitation with an array of transmit coilsMagnetic Resonance in Medicine, 2004
- Generalized autocalibrating partially parallel acquisitions (GRAPPA)Magnetic Resonance in Medicine, 2002
- SENSE: Sensitivity encoding for fast MRIMagnetic Resonance in Medicine, 1999
- The signal-to-noise ratio of nuclear magnetic resonance surface coils and application to a lossy dielectric cylinder model. II. The case of cylindrical window coilsIEEE Transactions on Biomedical Engineering, 1995
- Calculation of the signal-to-noise ratio for simple surface coils and arrays of coils [magnetic resonance imaging]IEEE Transactions on Biomedical Engineering, 1995
- High frequency volume coils for clinical NMR imaging and spectroscopyMagnetic Resonance in Medicine, 1994
- An efficient, highly homogeneous radiofrequency coil for whole-body NMR imaging at 1.5 TJournal of Magnetic Resonance (1969), 1985