MR image segmentation and bias field estimation using coherent local and global intensity clustering
Authors:
- 1 August 2010
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2, 578-582
Abstract
This paper presents a new energy minimization method for simultaneous image segmentation and bias field estimation of magnetic resonance (MR) images. The proposed algorithm introduces the global intensity into the algorithm CLIC and combines the local and global intensity information into account. The segmentation target therefore is driven by two forces, one induced by the coherent local intensity and the other by the coherent global intensity, to ensure the smoothness of the derived optimal bias field and improve the accuracy of the segmentations. An integration of the proposed algorithm defines an energy function ,then the segmentations and bias field estimation are simultaneously achieved by minimizing this function. Moreover, the proposed algorithm is robust to the parameter setting, thereby allowing fully automatic applications. The proposed method has been successfully applied to 3T and synthetic MR images with desirable results. Comparisons with other approaches demonstrate the superior performance of the proposed algorithm.Keywords
This publication has 14 references indexed in Scilit:
- MRI Tissue Classification and Bias Field Estimation Based on Coherent Local Intensity Clustering: A Unified Energy Minimization Framework2009
- Coil Sensitivity Estimation for Optimal SNR Reconstruction and Intensity Inhomogeneity Correction in Phased Array MR Imaging2005
- An adaptive spatial fuzzy clustering algorithm for 3-D MR image segmentationIEEE Transactions on Medical Imaging, 2003
- A modified fuzzy c-means algorithm for bias field estimation and segmentation of MRI dataIEEE Transactions on Medical Imaging, 2002
- Improved high resolution MR imaging for surface coils using automated intensity non‐uniformity correction: Feasibility study in the orbitJournal of Magnetic Resonance Imaging, 2001
- Segmentation of brain MR images through a hidden Markov random field model and the expectation-maximization algorithmIEEE Transactions on Medical Imaging, 2001
- Adaptive fuzzy segmentation of magnetic resonance imagesIEEE Transactions on Medical Imaging, 1999
- Optimized homomorphic unsharp masking for MR grayscale inhomogeneity correctionIEEE Transactions on Medical Imaging, 1998
- A nonparametric method for automatic correction of intensity nonuniformity in MRI dataIEEE Transactions on Medical Imaging, 1998
- Adaptive segmentation of MRI dataIEEE Transactions on Medical Imaging, 1996