A dual‐bending endoscope with shape‐lockable hydraulic actuation and water‐jet propulsion for gastrointestinal tract screening
- 28 October 2020
- journal article
- research article
- Published by Wiley in The International Journal of Medical Robotics and Computer Assisted Surgery
- Vol. 17 (1) , 1-13
Abstract
Background: Traditional flexible endoscopes are sophisticated medical devices that require frequent and expensive maintenance. Therefore, their implementation within low‐income and rural regions is challenging due to their high cost, complex sterilization process and poor portability.Aims: This paper aims to develop an endoscopic platform that is low‐cost, disposable and portable, with the primary goal of reducing gastric cancer‐related mortality among low‐ and middle‐income communities through wider access to regular screening programs.Materials and Methods: The endoscope employs a custom microvalve to switch between hydraulic actuation of a spatial bending fluidic actuator and water‐jet actuation. Three alloy wires with buckle attachments are connected to a pneumatic balloon which facilitates reversible shape‐locking of the actuator, and thus supports stable scanning by water‐jet actuation. Distal tip of the device has an internal charge‐coupled device camera for inspection.Results: Experiments demonstrated a 58% increase in the workspace after introduction of the water‐jet and more than three times the load‐locking ability variation. Phantom experiment was also conducted for performance comparison with a traditional endoscope.Conclusion: By controlling the pressure of supplied water and the inflation of locking balloon, the endoscope achieves a satisfactory workspace and a remarkable shape‐locking ability, demonstrating its potential clinical value in improving the prospects for upper gastrointestinal tract disease screening, especially gastric cancer.Keywords
Funding Information
- National Natural Science Foundation of China (51905374, 61773280)
- Engineering and Physical Sciences Research Council (EP/P027938/1)
This publication has 28 references indexed in Scilit:
- A Platform for Gastric Cancer Screening in Low- and Middle-Income CountriesIEEE Transactions on Biomedical Engineering, 2014
- Cancer incidence and mortality worldwide: Sources, methods and major patterns in GLOBOCAN 2012International Journal of Cancer, 2014
- Variable stiffness outer sheath with “Dragon skin” structure and negative pneumatic shape-locking mechanismInternational Journal of Computer Assisted Radiology and Surgery, 2014
- Global cancer transitions according to the Human Development Index (2008–2030): a population-based studyThe Lancet Oncology, 2012
- Multisociety guideline on reprocessing flexible gastrointestinal endoscopes: 2011Gastrointestinal Endoscopy, 2011
- Nonmetallic Rigid–Flexible Outer Sheath with Pneumatic Shapelocking Mechanism and Double Curvature StructureLecture Notes in Computer Science, 2011
- A novel device for rapid cleaning of poorly prepared colonsEndoscopy, 2010
- Estimates of worldwide burden of cancer in 2008: GLOBOCAN 2008International Journal of Cancer, 2010
- Low-Cost Tethered Capsule Endoscope (TCE) for Unsedated EsophagoscopyGastrointestinal Endoscopy, 2007
- Gastric cancer screening and subsequent risk of gastric cancer: A large‐scale population‐based cohort study, with a 13‐year follow‐up in JapanInternational Journal of Cancer, 2005