Comparisons of Localized Ionic Currents as Measured from 1-D and 3-D Vibrating Probes with Finite-Element Predictions for an Iron-Copper Galvanic Couple
Authors:
- 1 January 1988
- book chapter
- Published by ASTM International
- p. 118-135
Abstract
The ionic current density in the near-field of a corroding iron-copper galvanic couple was measured, and the results were compared with the predictions of a finite- element model, which calculates near-field potential and current density distributions. All three components of the ionic current density vector were measured using a three-dimensional vibrating microprobe. The calculated current densities were based on the measured polarization curves of the individual constituent materials forming the couple. Agreement between the predicted and measured results was excellent. Agreement between one-dimensional ionic current density distributions from previous work was also excellent.Keywords
This publication has 6 references indexed in Scilit:
- Ionic Current Densities in the Nearfield of a Corroding Iron‐Copper Galvanic CoupleJournal of the Electrochemical Society, 1986
- Steady growth cone currents revealed by a novel circularly vibrating probe: A possible mechanism underlying neurite growthJournal of Neuroscience Research, 1985
- Electrogalvanic Finite Element Analysis of Partially Protected Marine StructuresCorrosion, 1983
- Experimental optimization of current source-density technique for anuran cerebellumJournal of Neurophysiology, 1975
- AN ULTRASENSITIVE VIBRATING PROBE FOR MEASURING STEADY EXTRACELLULAR CURRENTSJournal of Cell Biology, 1974
- Thermal Agitation of Electricity in ConductorsPhysical Review B, 1928