Role of the Lens Capsule on the Mechanical Accommodative Response in a Lens Stretcher
Open Access
- 1 October 2008
- journal article
- research article
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 49 (10) , 4490-4496
Abstract
Purpose. To determine whether changes in elastic properties of the lens capsule ex vivo with age contribute to the forces necessary for accommodation. methods. Postmortem human (n = 22; age average: 41 ± 17years; range: 6–7) and cynomolgus monkey (n = 19; age average: 7.7 ± 1.8 years, range: 4.2–10) tissues including the lens, capsule, zonules, ciliary body, and sclera were mounted in an optomechanical lens-stretching system. Starting at 0 load, the sclera was symmetrically stretched to 2 mm in 0.25-mm steps at a speed of 0.1 mm · s−1. The load and lens diameter were measured at each step. The lens contents were removed through a mini-capsulorhexis. The stretching cycles were repeated on the empty capsular bag. The forces necessary to stretch the natural lens and empty bag were quantified as a function of age and compared. results. The force needed to stretch the empty lens capsule was independent of age (human, 2.6–34.9 g/mm [25.2–342.7 mN/mm]; monkey, 8.2–21.3 g/mm [80.3–208.6 mN/mm]). The ratio of the force necessary to stretch the empty lens capsule to the force necessary to stretch the natural lens decreased with age in the human and monkey lenses (P = 0.003, P = 0.72, respectively). conclusions. The mechanical properties of the empty lens capsule assessed ex vivo in a lens stretcher remain constant with age, suggesting that the changes in elasticity of the lens capsule do not play a significant role in presbyopia. In young eyes, the lens capsule determines the force necessary to stretch the whole lens. The age-related increase in force needed to stretch the lens is due to changes in the lens contents.Keywords
This publication has 31 references indexed in Scilit:
- Change in the accommodative force on the lens of the human eye with ageVision Research, 2008
- Optomechanical Response of Human and Monkey Lenses in a Lens StretcherInvestigative Ophthalmology & Visual Science, 2007
- Assessment of the strength of minicapsulorhexesJournal of Cataract & Refractive Surgery, 2006
- Accommodative Lens Refilling in Rhesus MonkeysInvestigative Ophthalmology & Visual Science, 2006
- Accommodative Changes in Lens Diameter in Rhesus MonkeysInvestigative Ophthalmology & Visual Science, 2006
- Noncontact Optical Measurement of Lens Capsule Thickness in Human, Monkey, and Rabbit Postmortem EyesInvestigative Ophthalmology & Visual Science, 2005
- Tensile mechanical and creep properties of Descemet's membrane and lens capsuleExperimental Eye Research, 2004
- Polymer Refilling of Presbyopic Human Lenses In Vitro Restores the Ability to Undergo Accommodative ChangesInvestigative Ophthalmology & Visual Science, 2003
- Small peripheral anterior continuous curvilinear capsulohexisJournal of Cataract & Refractive Surgery, 1999
- Model of the accommodative mechanism in the human eyeVision Research, 1982