Radiation Exposure in Transjugular Intrahepatic Portosystemic Shunt Creation
- 1 July 2015
- journal article
- research article
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 39 (2) , 210-217
Abstract
Purpose Transjugular intrahepatic portosystemic shunt (TIPS) creation is considered as being one of the most complex procedures in abdominal interventional radiology. Our aim was twofold: quantification of TIPS-related patient radiation exposure in our center and identification of factors leading to reduced radiation exposure. Materials and methods Three hundred and forty seven consecutive patients underwent TIPS in our center between 2007 and 2014. Three main procedure categories were identified: Group I (n = 88)—fluoroscopic-guided portal vein targeting, procedure done in an image intensifier-based angiographic system (IIDS); Group II (n = 48)—ultrasound-guided portal vein puncture, procedure done in an IIDS; and Group III (n = 211)—ultrasound-guided portal vein puncture, procedure done in a flat panel detector-based system (FPDS). Radiation exposure (dose-area product [DAP], in Gy cm2 and fluoroscopy time [FT] in minutes) was retrospectively analyzed. Results DAP was significantly higher in Group I (mean ± SD 360 ± 298; median 287; 75th percentile 389 Gy cm2) as compared to Group II (217 ± 130; 178; 276 Gy cm2; p = 0.002) and Group III (129 ± 117; 70; 150 Gy cm2 p < 0.001). The difference in DAP between Groups II and III was also significant (p < 0.001). Group I had significantly longer FT (25.78 ± 13.52 min) as compared to Group II (20.45 ± 10.87 min; p = 0.02) and Group III (19.76 ± 13.34; p < 0.001). FT was not significantly different between Groups II and III (p = 0.73). Conclusions Real-time ultrasound-guided targeting of the portal venous system during TIPS creation results in a significantly lower radiation exposure and reduced FT. Further reduction in radiation exposure can be achieved through the use of modern angiographic units with FPDS.Keywords
This publication has 32 references indexed in Scilit:
- Hepatic artery-targeting guidewire technique during transjugular intrahepatic portosystemic shuntBritish Journal of Radiology, 2011
- Direct Puncture of the Recanalized Paraumbilical Vein for Portal Vein Targeting During Transjugular Intrahepatic Portosystemic Shunt Procedures: Assessment of Technical Success and SafetyJournal of Vascular and Interventional Radiology, 2010
- Reference Levels for Patient Radiation Doses in Interventional Radiology: Proposed Initial Values for U.S. PracticeRadiology, 2009
- Enhancing Transjugular Intrahepatic Portosystemic Shunt Puncture by Using Three-dimensional Path Planning Based on the Back Projection of Two Two-dimensional PortographsRadiology, 2009
- Radiation exposure in interventional radiologyNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2007
- The Use of Carbon Dioxide Wedged Hepatic Venography to Identify the Portal Vein: Comparison with Direct Catheter Portography with Iodinated Contrast Medium and Analysis of Predictive Factors Influencing Level of OpacificationJournal of Vascular and Interventional Radiology, 2006
- Radiation Doses in Interventional Radiology Procedures: The RAD-IR Study Part I: Overall Measures of DoseJournal of Vascular and Interventional Radiology, 2003
- Portal venous branch targeting with a platinum-tipped wire to facilitate transjugular intrahepatic portosystemic shunt (TIPS) proceduresCardioVascular and Interventional Radiology, 1993
- Localization of the Portal Vein for Transjugular Catheterization: Percutaneous Placement of a Metallic Marker with Real-Time US GuidanceJournal of Vascular and Interventional Radiology, 1992
- Color Doppler-US guidance in transjugular placement of intrahepatic portosystemic shunts.Radiology, 1992