Abstract
A 2.54cm diameter punch and die set has been used in conjunction with a Mayes Hydraulic Machine to examine strain movements within the die of compacts maintained at constant stress. These were prepared from the bases Avicel PH 101 (AV), Sta-Rx 1500 (ST), Paracetamol DC (PC), Emdex (ED) and Eacompress (EC). Compression force and punch movements were simultaneously monitored using a CBM nicroconputer with disk storage of data. All compacts showed time dependent consolidation under constar. stress when held at ‘holding time’ of up to 60s. PC, AV and ST exhibited comparable movements but that of ED and EC ware less. Elastic recovery on sudden release of load was followed using machine code logging over a period of 90ms. Large recoveries were recorded for AV, PC and ST. If load release was immediate (zero holding time) then the recovery was greater when compared with recovery after holding tines of 30 and 60s, suggesting that some elastic energy was dissipated during the holding time. Elastic recovery of ED and EC was about half that of the other bases. Although these bases also showed reduced recovery with holding tine, percentage reduction was smaller than for the other bases. Following elastic recovery, a much slower viscoelastic movement could be demonstrated. It was difficult to clearly demarcate the division between viscoelastic and elastic movement but it appeared that the movement on viscoelastic consolidation was comparable to that en recovery when the load was removed. There are many references to tine dependent effects during tablet compression to be found in the literature. One of the earliest was due to Rees and Shotton (1) who found that the crushing strength of sodium chloride tablets could double after the lapse of one hour from ejection. This has recently been shown by Rue and Barkworth (2) to be due to the existence of a work hardened outer shell which inhibits relaxation by viscoelastic flow. Several authors (3,4,5) have investigated the stress decay that occurs when a tablet is held at a nominally constant force. Thus Wells and Langridge (5) monitored the fall from a peak pressure of 332MN/m2on a tablet prepared in a single punch machine turned by hand. Similar techniques have been described by Rees and Rue (3), Kiestand and others (4) and Shlanta and Milosovich (6). However as Rees and Rue have pointed out, these methods measure stress relaxation under constant strain conditions. Their results and conclusions differed from those of David and Augsburger (7) who compressed the same direct compression bases on a rotary tablet machine. In a rotary machine compression takes place under virtually constant, stress conditions because of the buffer effect of the powerful springs fitted to the compression wheels. This paper describes some techniques and observations on the compression of some direct compression bases using a Mayes Hydraulic Testing Machine (WH Mayes (Windsor) Ltd) which is capable of maintaining constant stress conditions on a compact formed in a punch and die set mounted between the platens.

This publication has 9 references indexed in Scilit: