Effect of Pneumatic Compression on Fibrinolysis After Total Hip Arthroplasty
Authors:
- William MacaulayWMWilliam Macaulay
- Geoffrey WestrichGWGeoffrey Westrich
- Nigel SharrockNSNigel Sharrock
- Thomas P. SculcoTSThomas P. Sculco
- Peter H. JhonPJPeter H. Jhon
- Margaret G.E. PetersonMPMargaret G.E. Peterson
- Eduardo A. SalvatiESEduardo A. Salvati
- 1 June 2002
- journal article
- clinical trial
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 399 (399) , 168-176
Abstract
The purpose of this prospective randomized clinical study was to investigate the enhanced systemic fibrinolysis mechanism of venous thrombosis prevention by pneumatic compression after total hip arthroplasty. Fifty patients were randomized into one of two groups (one with pneumatic compression [n=25] and one without [n=25]). Blood was drawn from a radial arterial line immediately preoperatively (baseline), at skin closure, and 8 hours and 22 hours after the baseline sample. Serum determinations of antigen of tissue plasminogen activator and plasminogen activator inhibitor-1 were done using enzyme-linked immunosorbent assays. These data do not support the enhancement of systemic fibrinolysis mechanism for lowering thromboembolic risk after total hip arthroplasty by pneumatic compression devices. The results of this study showed no differences that were statistically significant between the two groups. The greatest difference was observed 8 hours after surgery for the plasminogen activator inhibitor-1 marker, (28.12 with compression versus 22.07 ng/mL without); however, this result was not statistically significant. The beneficial effect of mechanical compression is more likely achieved through increased flow, local fibrinolytic effects, or both.Keywords
This publication has 16 references indexed in Scilit:
- External pneumatic compression and fibrinolysis in abdominal surgeryJournal of Vascular Surgery, 2000
- Efficacy of Prophylaxis Against Thromboembolism with Intermittent Pneumatic Compression After Primary and Revision Total Hip Arthroplasty*Journal of Bone and Joint Surgery, 1999
- Intermittent pneumatic compression of legs increases microcirculation in distant skeletal muscleJournal of Orthopaedic Research, 1999
- The Fibrinolytic Effects of Intermittent Pneumatic CompressionAnnals of Surgery, 1997
- Hemodynamic and Fibrinolytic Consequences of Intermittent Pneumatic CompressionThe Journal of Trauma: Injury, Infection, and Critical Care, 1996
- Venous hemodynamics during impulse foot pumpingJournal of Vascular Surgery, 1995
- Use of enoxaparin, a low-molecular-weight heparin, and unfractionated heparin for the prevention of deep venous thrombosis after elective hip replacement. A clinical trial comparing efficacy and safety. Enoxaparin Clinical Trial Group.Journal of Bone and Joint Surgery, 1994
- Prospective randomized trial of sequential compression devices vs low-dose warfarin for deep venous thrombosis prophylaxis in total hip arthroplastyThe Journal of Arthroplasty, 1991
- Thrombosis after hip replacement: Relationship to the fibrinolytic systemActa Orthopaedica, 1989
- EFFECT OF INTERMITTENT COMPRESSION OF THE ARMS ON DEEP VENOUS THROMBOSIS IN THE LEGSThe Lancet, 1976