Intraocular pressure variation during femtosecond laser–assisted cataract surgery using a fluid-filled interface
Authors:
- 1 January 2013
- journal article
- clinical trial
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 39 (1) , 22-27
Abstract
To evaluate intraocular pressure (IOP) during femtosecond laser-assisted cataract surgery using a fluid-filled interface. Ruhr University Eye Clinic, Bochum, Germany. Prospective clinical trial. The absolute IOP was measured with a modified Schiotz tonometer before and after laser-assisted cataract surgery with and without a fluid-filled interface (Liquid Optics interface, Catalys Precision Laser System). The study evaluated 100 eyes. Tonometry and laser cataract surgery were completed successfully in all eyes. The mean preoperative IOP was 15.6 mm Hg ± 2.5 (SD). Upon application of the suction ring and vacuum, the mean IOP rose to 25.9 ± 5.0 mm Hg and remained nearly constant after the laser procedure (27.6 ± 5.5 mm Hg). After removal of the suction ring, the mean IOP was 19.1 ± 4.4 mm Hg. The IOP 1 hour after surgery was not significantly higher than the preoperative values. The results indicate a minor increase in IOP using the fluid-filled interface. This is in strong contrast to substantially higher values reported in the literature with flat and curved applanating contact interfaces.Keywords
This publication has 19 references indexed in Scilit:
- Effect of Femtosecond Laser Cataract Surgery on the MaculaJournal of Refractive Surgery, 2011
- Internal Aberrations and Optical Quality After Femtosecond Laser Anterior Capsulotomy in Cataract SurgeryJournal of Refractive Surgery, 2011
- One million cataract surgeries: Swedish National Cataract Register 1992–2009Journal of Cataract & Refractive Surgery, 2011
- Femtosecond Laser Capsulotomy and Manual Continuous Curvilinear Capsulorrhexis Parameters and Their Effects on Intraocular Lens CentrationJournal of Refractive Surgery, 2011
- Comparison of Intraocular Lens Decentration Parameters After Femtosecond and Manual CapsulotomiesJournal of Refractive Surgery, 2011
- Femtosecond laser capsulotomyJournal of Cataract & Refractive Surgery, 2011
- Intraocular Pressure During Corneal Flap Preparation: Comparison Among Four Femtosecond Lasers in Porcine EyesJournal of Refractive Surgery, 2011
- Initial Clinical Evaluation of an Intraocular Femtosecond Laser in Cataract SurgeryJournal of Refractive Surgery, 2009
- Influence of Age on Retinal and Optic Nerve Head Blood CirculationOphthalmology, 1996
- Phaco-Emulsification and AspirationAmerican Journal of Ophthalmology, 1967