Use of phenol red thread tests to evaluate tear production in clinically normal Amazon parrots and comparison with Schirmer tear test findings
Authors:
- Eric S. StoreyESEric S. Storey
- Deborah A. CarboniDCDeborah A. Carboni
- Michael T. KearneyMKMichael T. Kearney
- Thomas N. TullyTTThomas N. Tully
- 15 November 2009
- journal article
- Published by American Veterinary Medical Association (AVMA) in Journal of the American Veterinary Medical Association
- Vol. 235 (10) , 1181-1187
Abstract
Objective—To determine phenol red thread test (PRTT) values in eyes of clinically normal Hispaniolan Amazon parrots before and after topical application of an ophthalmic anesthetic agent and compare findings with Schirmer tear test (STT) values. Design—Evaluation study. Animals—24 Amazona ventralis parrots from a research colony. Procedures—On 4 occasions (1-week intervals), all birds underwent a thorough ophthalmic examination of both eyes, which included (in sequence) performance of a PRTT and an STT; topical ocular application of proparacaine hydrochloride; and performance of another PRTT and another STT. Correlations between PRTT and STT values recorded with and without topical anesthesia were assessed. Results—Without topical anesthesia, mean ± SD PRTT value was 12.5 ± 5.0 mm/15 s (range, 1 to 25 mm/15 s). With topical anesthesia, the PRTT value was 12.6 ± 5.4 mm/15 s (range, 2 to 24 mm/15 s). Without topical anesthesia, mean STT value was 7.9 ± 2.6 mm/min (range, 0 to 13 mm/min). With topical anesthesia, the STT value was 5.1 ± 3.3 mm/min (range, 0 to 18 mm/min). The correlation of PRTT and STT values recorded with or without topical anesthesia was weak (r = 0.51 and r = 0.32, respectively). Conclusions and Clinical Relevance—Results indicated that the PRTT and STT were both viable methods for measurement of tear production in Hispaniolan Amazon parrots. Topical application of an ophthalmic anesthetic agent did not have a significant effect on the PRTT values but significantly decreased the STT values.Keywords
This publication has 16 references indexed in Scilit:
- Schirmer tear test, phenol red thread tear test, eye blink frequency and corneal sensitivity in the guinea pigVeterinary Ophthalmology, 2007
- Alterations of the ocular surface epithelial mucins 1, 2, 4 and the tear functions in patients with atopic keratoconjunctivitisClinical & Experimental Allergy, 2006
- Duration of effect and effect of multiple doses of topical ophthalmic 0.5% proparacaine hydrochloride in clinically normal dogsAmerican Journal of Veterinary Research, 2005
- Lacrimostimulants and lacrimomimeticsVeterinary Clinics of North America: Small Animal Practice, 2004
- Effects of laser in situ keratomileusis on tear production, clearance, and the ocular surfaceOphthalmology, 2001
- A comparison of corneal sensitivity between brachycephalic and Domestic Short‐haired catsVeterinary Ophthalmology, 2001
- Evaluation of aqueous tear production in dogs following general anesthesiaJournal of the American Animal Hospital Association, 2000
- Ulcerative keratitis associated with qualitative tear film abnormalities in catsVeterinary Ophthalmology, 1999
- The fluctuation of tear production in the dogJournal of the American Animal Hospital Association, 1998
- A Comparison of Corneal Sensitivity and Nerve Density in Albino and Pigmented RabbitsOphthalmic Research, 1978