Fatigue damage development in 10CrMo9-10 steel for power plant pipes in as-received state and after 280,000 h of exploitation
Authors:
Open Access
- 23 March 2023
- journal article
- research article
- Published by Springer Nature in Archives of Civil and Mechanical Engineering
- Vol. 23 (2) , 1-10
Abstract
This paper discusses an effect of 280,000 h of exploitation under internal pressure of 2.9 MPa and high temperature of 540 °C on the mechanical properties of 10CrMo9-10 (10H2M) power engineering steel. The mechanical response of the specimens obtained from two pipes: a new in the as-received state and exploited for a long period was assessed through the uniaxial tensile tests and subsequent fatigue tests. The long-term, high-temperature exposure of 10H2M steel resulted in the deterioration of its mechanical properties and was quantitatively described as a function of the fatigue damage measure, φ, and the fatigue damage parameter D. Finally, the proposed methodology of power exponent approximation with both damage sensitive parameters (φ, D) enabled for successful determination of the 10H2M steel fatigue life.Keywords
Funding Information
- Narodowe Centrum Nauki (2019/35/B/ST8/03151)
This publication has 17 references indexed in Scilit:
- Study of mechanism, microstructure and mechanical properties of activated flux TIG welded P91 Steel-P22 steel dissimilar metal jointMaterials Science and Engineering: A, 2018
- The role of local plasticity during very high cycle fatigue crack initiation in high-strength steelsInternational Journal of Fatigue, 2018
- Degradation of the Microstructure and Mechanical Properties of High-Chromium Steels Used in the Power Industry2018
- Effect of Long-Term Service on Microstructure and Mechanical Properties of Martensitic 9% Cr SteelJournal of Materials Engineering and Performance, 2017
- Study of the fracture surface morphology of impact and tensile tested cast and forged (C&F) Grade 91 steel at room temperature for different heat treatment regimesEngineering Failure Analysis, 2017
- Assessment of fatigue damage development in power engineering steel by local strain analysisMetallic Materials, 2016
- Analysis of High Temperature Steam Oxidation of Superheater Steels Used in Coal Fired BoilersOxidation of Metals, 2015
- Microstructural Degradation in Power Plant Steels and Life Assessment of Power Plant ComponentsProcedia Engineering, 2013
- Fracture2012
- Measurement of microstructure changes in 9Cr–1Mo and 2.25Cr–1Mo steels using an electromagnetic sensorScripta Materialia, 2012