A Double-Blind Randomized Controlled Trial of High Cutoff Versus Standard Hemofiltration in Critically Ill Patients With Acute Kidney Injury
- 1 October 2018
- journal article
- research article
- Published by Wolters Kluwer Health in Critical Care Medicine
- Vol. 46 (10) , e988-e994
Abstract
Objectives: In critically ill patients with acute kidney injury receiving vasopressors, high cytokine levels may sustain the shock state. High cutoff hemofiltration achieves greater cytokine removal in ex vivo and in animal models and may reduce the duration of shock but may also increase albumin losses. Design: This was a single-center double-blind randomized controlled trial comparing continuous venovenous hemofiltration-high cutoff to continuous venovenous hemofiltration-standard. Setting: Tertiary care hospital in Australia. Patients: Vasopressor-dependent patients in acute kidney injury who were admitted to the ICU. Interventions: Norepinephrine-free time were calculated in critically ill vasopressor-dependent patients in acute kidney injury, randomized to either continuous venovenous hemofiltration-high cutoff or continuous venovenous hemofiltration-standard. Measurement and Main Results: A total of 76 patients were randomized with the following characteristics (continuous venovenous hemofiltration-high cutoff vs continuous venovenous hemofiltration-standard); median age of 65 versus 70 year, percentage of males 47% versus 68%, and median Acute Physiology and Chronic Health Evaluation scores of 25 versus 23.5. The median hours of norepinephrine-free time at day 7 were 32 (0–110.8) for continuous venovenous hemofiltration-high cutoff and 56 hours (0–109.3 hr) (p = 0.520) for continuous venovenous hemofiltration-standard. Inhospital mortality was 55.6% with continuous venovenous hemofiltration-high cutoff versus 34.2% with continuous venovenous hemofiltration-standard (adjusted odds ratio, 2.49; 95% CI, 0.81–7.66; p = 0.191). There was no significant difference in time to cessation of norepinephrine (p = 0.358), time to cessation of hemofiltration (p = 0.563), and filter life (p = 0.21). Serum albumin levels (p = 0.192) were similar and the median dose of IV albumin given was 90 grams (20–212 g) for continuous venovenous hemofiltration-high cutoff and 80 grams (15–132 g) for continuous venovenous hemofiltration-standard (p = 0.252). Conclusions: In critically ill patients with acute kidney injury, continuous venovenous hemofiltration-high cutoff did not reduce the duration of vasopressor support or mortality or change albumin levels compared with continuous venovenous hemofiltration-standard.Keywords
This publication has 19 references indexed in Scilit:
- Sepsis and septic shockNature Reviews Disease Primers, 2016
- Techniques of extracorporeal cytokine removal: a systematic review of human studiesRenal Failure, 2013
- The inflammatory response in sepsisTrends in Immunology, 2013
- Techniques of Extracorporeal Cytokine Removal: A Systematic Review of the Literature on Animal Experimental StudiesThe International Journal of Artificial Organs, 2013
- Cytokines in Sepsis: Potent Immunoregulators and Potential Therapeutic Targets—An Updated ViewMediators of Inflammation, 2013
- Organ Crosstalk in Critically Ill Patients: Hemofiltration and Immunomodulation in SepsisBlood Purification, 2009
- Pilot study on the effects of high cutoff hemofiltration on the need for norepinephrine in septic patients with acute renal failure*Critical Care Medicine, 2006
- Acute Renal Failure in Critically Ill PatientsA Multinational, Multicenter StudyJAMA, 2005
- Interpreting the Mechanisms of Continuous Renal Replacement Therapy in Sepsis: The Peak Concentration HypothesisArtificial Organs, 2003
- Anti-Cytokine Therapies in Response to Systemic InfectionJournal of Investigative Dermatology Symposium Proceedings, 2001