LASIK Flap Creation With the Ziemer Femtosecond Laser in 787 Consecutive Eyes
Authors:
- Juhani PietiläJPJuhani Pietilä
- Anne HuhtalaAHAnne Huhtala
- Markus JääskeläinenMJMarkus Jääskeläinen
- Jarmo JylliJJJarmo Jylli
- Petri MäkinenPMPetri Mäkinen
- Hannu UusitaloHUHannu Uusitalo
- 1 January 2010
- journal article
- research article
- Published by SLACK, Inc. in Journal of Refractive Surgery
- Vol. 26 (1) , 7-16
Abstract
PURPOSE: To present the flap characteristics and short-term efficacy and safety of 787 consecutive LASIK procedures with the FEMTO LDV femtosecond laser (Ziemer Ophthalmic Systems) for the treatment of refractive errors.METHODS: Seven hundred eighty-seven consecutive eyes of 405 previously non-operated patients were treated with the FEMTO LDV. Intended flap thickness was 110 µm and intended flap diameter varied from 8.5 to 9.5 mm. Refractive treatment was performed with the WaveLight ALLEGRETTO WAVE Concerto 500 Hz excimer laser. All eyes were wavefront-optimized.RESULTS: The mean flap thickness, measured by ultra-sound pachymetry, was 90.0±5.5µm (range: 67 to 107µm) in right eyes and 90.1±4.6µm (range: 77 to 106µm) in left eyes. Mean flap diameter was 9.1±0.2 mm (range: 8.4 to 9.9 mm) in right eyes and 9.1±0.2 mm (range: 8.0 to 10.0 mm) in left eyes. Increasing flap thickness was correlated with increasing corneal thickness in right eyes and flatter keratometric value K1in left eyes. The most common complication was minor bleeding during the procedure (12.7%). All other complications were rare (8.4%), and none prevented further laser ablation.CONCLUSIONS: The Ziemer FEMTO LDV laser created thinner LASIK flaps than intended but with a low standard deviation and minimal intraoperative complications. [J Refract Surg. 2010;26:7–16.]Keywords
This publication has 36 references indexed in Scilit:
- Comparative micromorphologic in vitro porcine study of IntraLase and Femto LDV femtosecond lasersJournal of Cataract & Refractive Surgery, 2008
- Online optical coherence pachymetry as a safety measure for laser in situ keratomileusis treatment in 1859 casesJournal of Cataract & Refractive Surgery, 2008
- Flap thickness reproducibility in laser in situ keratomileusis with a femtosecond laser: Optical coherence tomography measurementJournal of Cataract & Refractive Surgery, 2008
- Femtosecond Laser versus Mechanical Microkeratome for LASIKOphthalmology, 2007
- Comparison of the corneal response to laser in situ keratomileusis with flap creation using the FS15 and FS30 femtosecond lasersJournal of Cataract & Refractive Surgery, 2007
- Corneal flap thickness with the Moria M2 single‐use head 90 microkeratomeActa Ophthalmologica Scandinavica, 2007
- Advances in refractive surgery: microkeratome and femtosecond laser flap creation in relation to safety, efficacy, predictability, and biomechanical stabilityCurrent Opinion in Ophthalmology, 2006
- One thousand consecutive IntraLase laser in situ keratomileusis flapsJournal of Cataract & Refractive Surgery, 2006
- Transient light sensitivity after femtosecond laser flap creation: Clinical findings and managementJournal of Cataract & Refractive Surgery, 2006
- Flap dimensions created with the IntraLase FS laserJournal of Cataract & Refractive Surgery, 2004