Adjusting intraocular lens power for sulcus fixation
Authors:
- Chikako SutoCSChikako Suto
- Sadao HoriSHSadao Hori
- Eriko FukuyamaEFEriko Fukuyama
- Junsuke AkuraJAJunsuke Akura
- 1 October 2003
- journal article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 29 (10) , 1913-1917
Abstract
To determine the appropriate correction of predicted intraocular lens (IOL) power for sulcus fixation and to prospectively assess the validity of the obtained correction value in patients having sulcus fixation. Department of Ophthalmology, Saiseikai Kurihashi Hospital, Saitama, Japan. The postoperative refraction, virtual in-the-bag IOL power for the same postoperative refraction, predicted refraction with an increase in in-the-bag IOL power by 0.50 to 2.00 diopters (D), and effective lens position (ELP) in 30 eyes with a normal axial length after sulcus fixation were retrospectively evaluated. The results were confirmed prospectively in 16 other eyes requiring sulcus fixation. A significant myopic shift (mean 0.78 D +/- 0.47 [SD]) from the predicted refraction occurred after sulcus fixation (P<.0001). The mean virtual IOL power was 1.11 +/- 0.67 D higher than that of the actual sulcus-fixated IOL. The difference between the predicted refraction and the refraction after sulcus fixation was less when the difference in IOL power was 1.00 D. The ELP of the IOLs was 0.75 mm shorter using A-mode measurement and 0.62 mm shorter using back calculation from the theoretical formula with sulcus fixation than with in-the-bag fixation. In the prospective study, there was a small refractive error (mean -0.06 +/- 0.19 D) when the planned IOL power was reduced by 1.00 D for sulcus fixation. For sulcus fixation in eyes with a normal axial length, the IOL power should be 1.00 D less than the power for in-the-bag fixation.Keywords
This publication has 7 references indexed in Scilit:
- International Intraocular Lens & Implant Registry 2002Journal of Cataract & Refractive Surgery, 2002
- Intraocular lens tilt and decentration, anterior chamber depth, and refractive error after trans-scleral suture fixation surgery11The authors have no proprietary interest in any of the materials described in this article.Ophthalmology, 1999
- Standardizing constants for ultrasonic biometry, keratometry, and intraocular lens power calculationsJournal of Cataract & Refractive Surgery, 1997
- Ultrasound velocities for axial eye length measurementJournal of Cataract & Refractive Surgery, 1994
- Sources of error in intraocular lens power calculationJournal of Cataract & Refractive Surgery, 1992
- A three-part system for refining intraocular lens power calculationsJournal of Cataract & Refractive Surgery, 1988
- Accuracy of Ultrasound Intraocular Lens CalculationArchives of Ophthalmology (1950), 1981