Liquid electrode dielectric barrier discharge for the analysis of solved metals
- 21 July 2011
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 26 (10) , 1974-1978
Abstract
A miniaturised dielectric barrier discharge at atmospheric pressure is used for the detection of metals dissolved in liquids by means of optical emission spectrometry. The plasma is formed inside a fused silica capillary with an inner diameter of 700 μm between the flowing liquid surface and a tungsten electrode with 400 μm diameter. In this case, the flowing liquid with 1 mol L−1nitric acid forms the other electrode of the plasma. A liquid flow rate of 20 μL min−1 is used and the pulsed high voltage with 3.2 kVpp and 87 kHz is dielectric coupled into the liquid over a copper coating on the outer capillary surface, where the dielectric barrier is formed by the wall of the capillary. Disequilibrium between the liquid flow rate and transfer rate into the plasma causes a pulsation of the discharge. This pulsation shows a positive effect on the long-term stability of the discharge, where the discharge can be sustained in the range of one hour and more. The stability of the discharge is influenced also by the nitric acid concentration and therefore the conductivity of the liquid. Calibration measurements are performed for several alkali, alkaline earth metals and silver. Detection limits are determined between 0.02 mg L−1 for potassium and 6.9 mg L−1 for barium. Together with the achieved stability and low flow rate the application as a monitoring device in flow systems or coupling with micro-separation devices seems possible.Keywords
This publication has 24 references indexed in Scilit:
- Dielectric barrier discharges in analytical chemistryThe Analyst, 2011
- Electronic coupling and scaling effects during dielectric barrier electrospray ionizationAnalytical and Bioanalytical Chemistry, 2011
- Characterization of dielectric barrier electrospray ionization for mass spectrometric detectionAnalytical and Bioanalytical Chemistry, 2010
- Exploring microdischarges for portable sensing applicationsAnalytical and Bioanalytical Chemistry, 2009
- Atomic SpectroscopyAnalytical Chemistry, 2008
- Analytical Detectors Based on Microplasma SpectrometryPlasma Chemistry and Plasma Processing, 2007
- Some trends in the development of microplasmas for spectrochemical analysisAnalytical and Bioanalytical Chemistry, 2004
- Microplasmas for analytical spectrometryJournal of Analytical Atomic Spectrometry, 2003
- Spectral detection of metal contaminants in water using an on-chip microglow dischargeIEEE Transactions on Electron Devices, 2002
- Miniaturized total chemical analysis systems: A novel concept for chemical sensingSensors and Actuators B: Chemical, 1990