Small‐signal stability and fault performance of mixed grid forming and grid following offshore wind power plants connected to a HVDC‐diode rectifier
Open Access
- 22 July 2020
- journal article
- research article
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 14 (12) , 2166-2175
Abstract
This study aims at validating the simultaneous operation of grid following and grid forming wind power plants when connected to a common diode rectifier‐based HVDC link. The controllers for both grid forming and grid following wind turbines include fault‐ride‐through capability with soft restoration of the off‐shore AC‐grid. Current and voltage controllers are developed in the stationary reference frame. The presented control and soft restoration strategies are based on local measurements only and do not require communication between wind turbine generators. The small‐signal stability analysis of the mixed system in multiple d – q axis using detailed string models is carried out in order to show the sensitivity to grid following phase‐locked‐loop gains and to grid forming droop gains. Interoperability between grid forming and grid following wind turbines during transients is shown by means of detailed simulation during symmetric faults in different locations of the off‐shore grid.Keywords
This publication has 24 references indexed in Scilit:
- Distributed PLL-Based Control of Offshore Wind Turbines Connected With Diode-Rectifier-Based HVDC SystemsIEEE Transactions on Power Delivery, 2017
- Enhanced Voltage Control of VSC-HVDC-Connected Offshore Wind Farms Based on Model Predictive ControlIEEE Transactions on Sustainable Energy, 2017
- Structural Resemblance Between Droop Controllers and Phase-Locked LoopsIEEE Access, 2016
- Three-Phase PLLs: A Review of Recent AdvancesIEEE Transactions on Power Electronics, 2016
- High-Performance Digital Resonant Controllers Implemented With Two IntegratorsIEEE Transactions on Power Electronics, 2010
- Design and Analysis of the Droop Control Method for Parallel Inverters Considering the Impact of the Complex Impedance on the Power SharingIEEE Transactions on Industrial Electronics, 2010
- Decoupled Double Synchronous Reference Frame PLL for Power Converters ControlIEEE Transactions on Power Electronics, 2007
- Proportional-resonant controllers and filters for grid-connected voltage-source convertersIEE Proceedings - Electric Power Applications, 2006
- Output Impedance Design of Parallel-Connected UPS Inverters With Wireless Load-Sharing ControlIEEE Transactions on Industrial Electronics, 2005
- Stationary frame current regulation of PWM inverters with zero steady-state errorIEEE Transactions on Power Electronics, 2003