Differential leukocyte counts determined in chicken blood using the Cell‐Dyn 3500
- 1 September 2004
- journal article
- research article
- Published by Wiley in Veterinary Clinical Pathology
- Vol. 33 (3) , 133-138
Abstract
Background: Automated hematology instruments commonly are used for mammalian blood analysis, but there is a lack of accurate automated methods available for avian leukocyte analysis. Objective: The aim of this study was to validate differential leukocyte counts in blood from chickens using the Cell‐Dyn 3500 hematology system and avian‐specific software.Methods: Blood samples were collected in lithium‐heparin tubes from 2 groups (n = 84 and n = 139) of laying hens. Manual 200‐cell differential counts were done on routinely‐stained blood smears, and manual total granulocyte counts (heterophils and eosinophils) were done using an eosinophil stain in a counting chamber. Automated differential counts were done using VET 2.3, a research and development version of avian‐specific software for the Cell‐Dyn 3500. Results were analyzed using Pearson's correlation and difference plots.Results: Automated granulocyte counts from the Cell‐Dyn were in good agreement with manual granulocyte counts (r= 0.93 and 0.80 for the 2 study groups). No correlation was found between automated and manual lymphocyte counts. Correlation coefficients for monocyte counts were 0.70 and 0.43. Conclusion: Automated leukocyte results from the Cell‐Dyn using VET 2.3 software were not fully accurate. Total granulocyte counts may be of clinical usefulness, but results obtained for other parameters were unreliable.Keywords
This publication has 9 references indexed in Scilit:
- Effect of Nest Design, Passages, and Hybrid on Use of Nest and Production Performance of Layers in Furnished CagesPoultry Science, 2002
- A New Method for Counting of Quail Leukocytes by Flow Cytometry.Journal of Veterinary Medical Science, 2002
- The avian heterophil leucocyte: a reviewWorld's Poultry Science Journal, 1998
- Automated Differential Leukocyte Count in Horses, Cattle, and Cats Using the Technicon H‐1E Hematology SystemVeterinary Clinical Pathology, 1996
- Comparing Laboratory Tests Using the Difference Plot MethodVeterinary Clinical Pathology, 1993
- Measurement in Medicine: The Analysis of Method Comparison StudiesJournal of the Royal Statistical Society: Series D (The Statistician), 1983
- Observations on the Use of a Semi-Automatic System for Haematological Measurements in BirdsBritish Veterinary Journal, 1977
- The Application of An Electronic Particle Counter with A Mean Cell Volume Computer and An Hematocrit Accessory to Avian HematologyPoultry Science, 1977
- A New Blood Diluent for Counting the Erythrocytes and Leucocytes of the ChickenPoultry Science, 1952