The Effect of Temperature on Soft Contact Lens Diameter
Authors:
- Matthew PottsMPMatthew Potts
- Anna SulleyASAnna Sulley
- 1 September 2016
- journal article
- Published by Wolters Kluwer Health in Eye & Contact Lens: Science & Clinical Practice
- Vol. 42 (5) , 298-302
Abstract
The diameters of soft contact lenses are conventionally measured at room temperature (RT), however, all soft lenses shrink when raised to eye temperature (ET). The purpose of this study was to evaluate RT to ET shrinkage in a representative sample of contemporary spherical soft contact lenses. Twenty-four reusable and daily disposable lens types (10 hydrogel and 14 silicone hydrogel) in three powers were measured for total diameter at RT (20°C±1°C) and ET (34°C±1°C). Lens diameter measurements were undertaken after equilibration in ISO saline in a temperature controlled lens analyzer (Optimec Ltd, Malvern, UK). Theoretical changes in base curve radii were also calculated. All lens types reduced in diameter when raised to ET. The largest mean changes with silicone hydrogel and hydrogel lenses were with Avaria (Δ0.33 mm) and SofLens Daily Disposable (Δ0.69 mm), respectively. The smallest mean changes for silicone hydrogel and hydrogel lenses were with 1-DAY ACUVUE TruEye (Δ0.04 mm) and SofLens 38 (Δ0.11 mm), respectively. There was, however, a wide range in change between the different lenses tested. This study has identified the levels of shrinkage in current soft contact lenses. In many cases, these shrinkage levels can be expected to have significant effects on clinical performance.Keywords
This publication has 9 references indexed in Scilit:
- Mathematical Model for Evaluating Soft Contact Lens FitOptometry and Vision Science, 2014
- Lens parameter changes under in vitro and ex vivo conditions and their effect on the conjunctivaContact Lens and Anterior Eye, 2013
- Factors Affecting Corneoscleral TopographyInvestigative Ophthalmology & Visual Science, 2013
- The Effect of Temperature on Soft Contact Lens Modulus and DiameterEye & Contact Lens: Science & Clinical Practice, 2011
- Variations in the corneal surface temperature with contact lens wearProceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 2007
- Ocular Surface TemperatureEye & Contact Lens: Science & Clinical Practice, 2005
- In vitro evaluation of the dehydration characteristics of silicone hydrogel and conventional hydrogel contact lens materialsContact Lens and Anterior Eye, 2002
- Environment-sensitive hydrogels for drug deliveryAdvanced Drug Delivery Reviews, 2001
- Water properties of hydrogel contact lens materials: a possible predictive model for corneal desiccation stainingBiomaterials, 1993