Chronic nerve root entrapment: compression and degeneration
- 21 January 2013
- journal article
- review article
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 10 (1) , 011001
Abstract
Electrode mounts are being developed to improve electrical stimulation and recording. Some are tight-fitting, or even re-shape the nervous structure they interact with, for a more selective, fascicular, access. If these are to be successfully used chronically with human nerve roots, we need to know more about the possible damage caused by the long-term entrapment and possible compression of the roots following electrode implantation. As there are, to date, no such data published, this paper presents a review of the relevant literature on alternative causes of nerve root compression, and a discussion of the degeneration mechanisms observed. A chronic compression below 40 mmHg would not compromise the functionality of the root as far as electrical stimulation and recording applications are concerned. Additionally, any temporary increase in pressure, due for example to post-operative swelling, should be limited to 20 mmHg below the patient's mean arterial pressure, with a maximum of 100 mmHg. Connective tissue growth may cause a slower, but sustained, pressure increase. Therefore, mounts large enough to accommodate the root initially without compressing it, or compliant, elastic, mounts, that may stretch to free a larger cross-sectional area in the weeks after implantation, are recommended.Keywords
This publication has 68 references indexed in Scilit:
- CERVICAL RADICULOPATHYNeurosurgery, 2007
- An electrophysiological method for measuring the potassium permeability of the nerve perineuriumBrain Research, 1997
- Laser Doppler Study of Porcine Cauda Equina Blood FlowSpine, 1995
- The first 500 patients with sacral anterior root stimulator implants: general descriptionSpinal Cord, 1994
- Long-term follow-up of patients with sacral anterior root stimulator implantsSpinal Cord, 1990
- Sacral anterior root stimulators for bladder control in paraplegia: the first 50 cases.Journal of Neurology, Neurosurgery & Psychiatry, 1986
- Structural properties of spinal nerve roots: BiomechanicsExperimental Neurology, 1986
- Effect of graded ligature compression on nerve conductionExperimental Neurology, 1983
- Sacral anterior root stimulators for bladder control in paraplegiaSpinal Cord, 1982
- An implant to empty the bladder or close the urethra.Journal of Neurology, Neurosurgery & Psychiatry, 1977