Formation of phosphopeptide‐metal ion complexes in liquid chromatography/electrospray mass spectrometry and their influence on phosphopeptide detection
- 31 August 2005
- journal article
- research article
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 19 (19) , 2747-2756
Abstract
Despite major advances in mass spectrometry, the detection of phosphopeptides by liquid chromatography with electrospray mass spectrometry (LC/ES‐MS) still remains very challenging in proteomics analysis. Phosphopeptides do not protonate efficiently due to the presence of one or more acidic phosphate groups, making their detection difficult. However, other mechanisms also contribute to the difficulties in phosphopeptide analysis by LC/ES‐MS. We report here on one such undocumented problem: the formation of phosphopeptide‐metal ion complexes during LC/ES‐MS. It is demonstrated that both synthetic phosphopeptides and phosphopeptides from bovine β ‐casein and α ‐casein form phosphopeptide‐metal ion complexes containing iron and aluminum ions, resulting in a dramatic decrease in signal intensity of the protonated phosphopeptides. The interaction of phosphopeptides with metal ions on the surface of the C18 stationary phase is also shown to alter their chromatographic behavior on reversed‐phase columns such that the phosphopeptides, especially multiply phosphorylated peptides, become strongly retained and very difficult to elute. The sources of iron and aluminum are from the solvents, stainless steel, glassware and C18 material. It was also found that, upon addition of EDTA, the formation of the phosphopeptide‐metal ion complex is diminished, and the phosphopeptides that did not elute from the LC column can now be detected efficiently as protonated molecules. The sensitivity of detection was greatly increased such that a tetra‐phosphorylated peptide, RELEELNVPGEIVEpSLpSpSpSEESITR from the tryptic digestion of bovine β ‐casein, was detected at a limit of detection of 25 fmol, which is 400 times lower than without EDTA. Copyright © 2005 John Wiley & Sons, Ltd.Keywords
This publication has 37 references indexed in Scilit:
- Phosphoric Acid as a Matrix Additive for MALDI MS Analysis of Phosphopeptides and PhosphoproteinsAnalytical Chemistry, 2004
- Phosphoric acid enhances the performance of Fe(III) affinity chromatography and matrix‐assisted laser desorption/ionization tandem mass spectrometry for recovery, detection and sequencing of phosphopeptidesRapid Communications in Mass Spectrometry, 2004
- Selective Isolation at the Femtomole Level of Phosphopeptides from Proteolytic Digests Using 2D-NanoLC-ESI-MS/MS and Titanium Oxide PrecolumnsAnalytical Chemistry, 2004
- Improved Detection of Hydrophilic Phosphopeptides Using Graphite Powder Microcolumns and Mass SpectrometryMolecular & Cellular Proteomics, 2004
- Assembly of Cell Regulatory Systems Through Protein Interaction DomainsScience, 2003
- Nanoelectrospray‐based detection and sequencing of substoichiometric amounts of phosphopeptides in complex mixturesJournal of Mass Spectrometry, 2003
- Phosphoproteome analysis by mass spectrometry and its application to Saccharomyces cerevisiaeNature Biotechnology, 2002
- Signaling—2000 and BeyondCell, 2000
- Evidence for phosphorylation of serine 753 in CFTR using a novel metal‐ion affinity resin and matrix‐assisted laser desorption mass spectrometryProtein Science, 1997
- Study of Al3+ binding and conformational properties of the alanine-substituted C-terminal domain of the NF-M protein and its relevance to Alzheimer's diseaseBiochemistry, 1994