Acute and steady-state insulin responses to glucose in nonobese diabetic subjects
Authors:
- Roger L. LernerRLRoger L. Lerner
- Daniel PorteDPDaniel Porte
Open Access
- 1 July 1972
- journal article
- clinical trial
- Published by American Society for Clinical Investigation in Journal of Clinical Investigation
- Vol. 51 (7) , 1624-1631
Abstract
Previous observations in normal subjects have suggested that when 5-g glucose pulses (P) were given in the following sequence: before (P1) and 45 min after beginning a 300 mg/min glucose infusion (P2); during the 20th hr (P3) and 1 hr after the infusion was stopped (P4); the insulin responses were consistent with a simple two-pool model. One pool is a readily available small storage pool which is refilled by a second, larger, more slowly responding pool that controls basal and steady-state insulin output. The identical protocol was employed to evaluate the insulin responses in 13 nonobese diabetic subjects. Diabetics had basal insulin levels indistinguishable from normals (diabetics: 10.7±4; normals: 10.7±5, mean ±SD, μU/ml), but had significantly elevated basal glucose levels (diabetics: 161±27; normals: 88±7, mg/100 ml, P < 0.05). The mean early insulin response (3-5 min Δ IRI) after a 5 g glucose pulse (P1) was significantly diminished in diabetics (diabetics 6.4±9; normals: 32.5±14, μU/ml, P < 0.01) consistent with a defective storage pool output. The glucose disappearance rate, KG, decreased in parallel with the early insulin response and the slope of the regression line between these two variables was virtually identical with that calculated from 16 normal subjects. Similar to normal subjects, during the short glucose infusion, the acute insulin response to P2 was diminished in diabetics (P < 0.02). In normal subjects after 20 hr of infusion, the rapid insulin responses to P3 are restored to the preinfusion P1 values, and 1 hr after the infusion was stopped, the responses to P4 are increased twofold (P < 0.001). Diabetics, however, demonstrated decreased early responses to P3 (P < 0.001) and no increased response to P4. In contrast to the diminished acute insulin responses to glucose pulses, diabetics have steady-state insulin levels after 20 hr of glucose infusion similar to those of normal subjects (diabetics: 25.7±13; normals: 32.5±14, μU/ml). Thus both basal and steady-state insulin levels of diabetics were comparable with those of normal subjects, which suggest that although the rapid insulin response from the storage pool output is defective in diabetics, the more slowly responding pool is intact.Keywords
This publication has 21 references indexed in Scilit:
- Proinsulin-like component of circulating insulin in the basal state and in patients and hamsters with islet cell tumorsJournal of Clinical Investigation, 1971
- Relationships Between Intravenous Glucose Loads, Insulin Responses and Glucose Disappearance Rate1The Journal of Clinical Endocrinology & Metabolism, 1971
- Portal Vein Insulin Concentrations in Diabetic SubjectsDiabetes, 1971
- Insulin responses to glucose: evidence for a two pool system in manJournal of Clinical Investigation, 1969
- Plasma insulin: fluctuations in the “big” insulin component in man after glucose and other stimuliJournal of Clinical Investigation, 1969
- The relationship between endogenous serum insulin concentration and glucose uptake in the forearm muscles of nondiabeticsJournal of Clinical Investigation, 1968
- Plasma Insulin Responses to Glucose and Tolbutamide of Normal Weight and Obese Diabetic and Nondiabetic SubjectsDiabetes, 1966
- Glucose Dynamics in Normal Subjects and Diabetic Patients before and after a Glucose LoadDiabetes, 1966
- Effect of Glucose Dose Upon Intravenous Glucose Tolerance in Health and in DiabetesThe Journal of Clinical Endocrinology & Metabolism, 1963