Stent expansion of restrictive Fontan conduits to nominal diameter and beyond
- 2 November 2022
- journal article
- research article
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 100 (6) , 1059-1066
Abstract
Background: Mechanical factors may cause bottlenecks in a Fontan circuit. Extracardiac conduits (ECC) are placed at a young age, but the materials do not allow growth. Restriction in ECC dimensions may deteriorate the function of the circuit.Aims: This study aimed to evaluate the feasibility and safety of stent expansion of an ECC to the nominal dimension at the time of implant and, if possible, beyond nominal.Methods: Retrospective, single‐center observational review of all ECC Fontan patients who received a stent to expand a previously placed surgical conduit.Results: A total of 44 restrictive conduits were stented over a 14‐year study period with a median of 11.8 (interquartile ranges [IQR]: 9.1−13.8) years after ECC placement. Cross‐sectional areas were a median of 30% (IQR: 21−42) smaller than the originally placed ECC; there was no gradient in 23/44 patients and in 21/44, a minimal gradient of 1.3 ± 0.5 (range 1−3 mmHg). All conduits could be enlarged with a significant (p < 0.0001) increase in diameter from 13.6 ± 1.8 to 19.2 ± 1.2 mm, corresponding to a median cross‐sectional area increase of 171% (IQR: 153−220). In three patients where the conduits were not contracted, expansion of between 127% and 165% was obtained. There were no conduit ruptures and only one minor complication.Conclusions: ECC in some Fontan patients become smaller than nominal over time, usually without overt symptoms. The dimensions of ECC's can be safely and significantly increased to nominal or even beyond employing stenting. It allows adjustment of ECC dimensions to compensate for somatic growth.Keywords
Funding Information
- Fonds Wetenschappelijk Onderzoek
This publication has 30 references indexed in Scilit:
- Outcomes of Stent Implantation for Obstruction of Intracardiac Lateral Tunnel Fontan PathwaysCirculation: Cardiovascular Interventions, 2013
- Stent therapy for acute and chronic obstructions in extracardiac Fontan conduitsCardiology in the Young, 2012
- Longitudinal growth of the autologous vessels above and below the Gore-Tex graft after the extracardiac conduit Fontan procedure☆European Journal of Cardio-Thoracic Surgery, 2010
- The Fontan circulation: who controls cardiac output?Interactive CardioVascular and Thoracic Surgery, 2010
- What Limits Cardiac Performance during Exercise in Normal Subjects and in Healthy Fontan Patients?International Journal of Pediatrics, 2010
- Stent expansion of stretch Gore‐Tex grafts in children with congenital heart lesionsCatheterization and Cardiovascular Interventions, 2009
- Midterm follow-up of the status of Gore-Tex graft after extracardiac conduit Fontan procedure☆European Journal of Cardio-Thoracic Surgery, 2007
- Optimal conduit size for extracardiac Fontan operation✩European Journal of Cardio-Thoracic Surgery, 2000
- Extracardiac Fontan operation for complex cardiac anomalies: Seven years' experienceThe Journal of Thoracic and Cardiovascular Surgery, 1997
- THE BLOOD FLOW IN THE CAVAL VEINS AT REST AND DURING EXERCISE IN NORMAL SUBJECTSActa Medica Scandinavica, 1968