Direct Beam Radiation Exposure to Surgeons During Pinning of Supracondylar Humerus Fractures
Authors:
- 1 March 2014
- journal article
- upper extremity
- Published by Wolters Kluwer Health in Journal of Pediatric Orthopaedics
- Vol. 34 (2) , 166-171
Abstract
Background: Direct beam radiation exposure to the surgeon, especially to their hands, is extremely common during supracondylar humerus fracture pinnings and results in exposure to significantly greater doses of ionizing radiation when compared with scatter radiation. The purpose of this study was to determine how often surgeons are exposed to direct beam radiation during this surgery and whether the C-arm position and the surgeon’s experience influence radiation exposure. Methods: In this double blind study, we collected 3842 fluoroscopic still images from 78 closed reduction and percutaneous pinning surgeries for supracondylar humerus fractures performed or supervised by 6 attending surgeons. The percentage of images containing a surgeon’s body was calculated as an indicator of direct beam radiation exposure. Total fluoroscopy time, C-arm position (standard or inverted), and whether the primary surgeon was an attending, resident, or both were recorded. Nonparametric statistical analyses were performed. Results: Fluoroscopy lasted for a median of 34 seconds, and the surgeon was exposed to direct beam radiation in a median of 13% of fluoroscopy films, with exposure ranging from 0% to 97% per surgery. Fluoroscopy was significantly longer when the C-arm position was inverted when compared with the standard position (43 vs. 26 s, P=0.034). Surgeons’ exposure to direct beam radiation was also slightly greater when the C-arm position was inverted (16% vs. 10%, P=0.087). The duration of fluoroscopy exposure and the percentage of films with the body exposed to radiation did not differ based on whether the surgery was performed by an attending, a resident, or both (P=0.53 and 0.28, respectively). However, the percentage of films with bodily radiation exposure did significantly differ between the attending physicians (P=0.029). Conclusions: Direct beam radiation exposure varied widely between surgeries and surgeons, ranging from none to nearly constant exposure. Surgical time also significantly increased with the C-arm in the inverted position compared with the standard position. Given the significant variation in exposure between attending physicians, it is likely that exposure to direct beam radiation can be avoided with improved awareness about the risk of direct beam radiation exposure and cautious surgical technique. Level of Evidence: Not applicable.Keywords
This publication has 17 references indexed in Scilit:
- Accuracy of Intraoperative Fluoroscopy with and without Laser Guidance in Foot and Ankle SurgeryFoot & Ankle International, 2012
- Reducing Occupational Exposure From FluoroscopyJournal of the American College of Radiology, 2007
- Response to Hafez et al.’s “Radiation exposure to the hands of orthopaedic surgeons: are we underestimating the risk?”Archives of orthopaedic and trauma surgery, 2005
- Radiation Exposure to the Hands From Mini C-Arm FluoroscopyThe Journal of Hand Surgery, 2005
- Radiation exposure using laser aiming guide in orthopaedic proceduresAnz Journal of Surgery, 2002
- Radiation Exposure with Use of the Inverted-C-Arm Technique in Upper-Extremity SurgeryJournal of Bone and Joint Surgery, 2001
- The Effects, Risks, and Guidelines for Radiation Use in Orthopaedic SurgeryClinical Orthopaedics and Related Research, 2000
- A simple laser guide to reduce the screening time during the insertion of dynamic hip screwsInjury, 1998
- The Risk from Radiation Exposure during Operative X-ray Screening in Hand SurgeryJournal of Hand Surgery (European Volume), 1994
- Radiation exposure to the hands of orthopaedic surgeons during procedures under fluoroscopic X-ray controlBritish Journal of Radiology, 1993