A novel method to ascertain sample mass thickness and matrix effects for X‐ray fluorescence element determinations
Author:
- 1 July 1994
- journal article
- research article
- Published by Wiley in X-Ray Spectrometry
- Vol. 23 (4) , 160-168
Abstract
An x‐ray fluorescence method was developed for the determination of both trace and major elements in environmental samples that are primarily of geochemical origin. For analysis, unweighed finely pulverized sample material is lightly compressed to a mass thickness between 0.1 and 0.4 g cm −2 . The method utilizes the relative intensities of two incoherent and one coherent scattered excitation radiation to ascertain the sample mass thickness and the photoelectric cross‐section of the sample for the excitation radiation. This information is employed to calculate matrix absorption and enhancement effect corrections required for the individual element determinations. The intensity of one of the incoherently scattered radiations serves as an internal standard for all of the element determinations. The capability of the method has been demonstrated with three US National Institute of Standards and Technology reference materials. The concentrations of sixteen trace elements (Mn, Ni, Cu, Zn, Ga, As, Se, Br, Rb, Sr, Y, Zr, Nb, Ba, Pb, and Th) and four major elements (K, Ca, Ti, and Fe) were determined from one x‐ray spectrum which was acquired over a 1000 s counting interval.Keywords
This publication has 8 references indexed in Scilit:
- High‐precision non‐destructive x‐ray fluorescence method applicable to establishing the provenance of obsidian artifactsX-Ray Spectrometry, 1993
- Trace element determination using synchrotron radiationAnalytical Chemistry, 1986
- Trace element analysis of silicates by means of energy‐dispersive x‐ray spectrometryX-Ray Spectrometry, 1984
- Energy‐dispersive x‐ray fluorescence analysis of silicate rocks for major and trace elementsX-Ray Spectrometry, 1984
- Absorption correction via scattered radiation in energy-dispersive x-ray fluorescence analysis for samples of variable composition and thicknessAnalytical Chemistry, 1980
- Energy dispersive x-ray fluorescence spectrometry for determination of twenty-six trace and two major elements in geochemical specimensAnalytical Chemistry, 1977
- A simple method for background and matrix correction of spectral peaks in trace element determination by X‐ray fluorescence spectrometryX-Ray Spectrometry, 1976
- Scattered X-Rays as Internal Standards in X-Ray Emission SpectroscopyAnalytical Chemistry, 1958