Lid speculum as effective active and reference electrodes for electroretinography recording in normal rabbits
Preprint
Abstract
Purpose: Although electroretinography (ERG) is vital for evaluating retinal function, conventional corneal electrodes slide or detach in animals. This study aimed to investigate the effectiveness of a novel approach to ERG recording using a metal eyelid speculum for both active and reference electrodes in conjunction with a skin electrode-based ERG device. Methods: We tested a stainless-steel eyelid speculum as both active and reference electrodes with a skin-electrode ERG system (HE-2000vet) in six healthy Japanese White rabbits. Dark-adapted rod and maximal responses and light-adapted cone and 30 Hz flicker ERGs were recorded in three weekly sessions. Results: Reproducible waveforms with identifiable a- and b-waves were obtained in every eye; rod b-waves reached 50–90 µV and cone b-waves 40–55 µV. Intraclass correlation coefficients revealed substantial interocular agreement and moderate-to-substantial inter-session reproducibility for b-wave amplitude and implicit time, whereas a-wave metrics were less reliable owing to lower amplitudes. The advantages of speculum electrode over corneal electrodes are that it requires no fur shaving, maintains stable contact regardless of globe orientation, and allows real-time observation. Conclusions: This study demonstrated that an eyelid-speculum electrode is a practical, non-invasive alternative for veterinary and experimental ERG recordings, producing signal quality sufficient for longitudinal and interocular analyses while avoiding cosmetic and technical drawbacks of conventional methods.Keywords
Funding Information
- Japan Society of Physiological Anthropology (25K03446)
- Japan Society of Physiological Anthropology (23K09056)
- Takahashi Industrial and Economic Research Foundation
This publication has 5 references indexed in Scilit:
- ISCEV Standard for full-field clinical electroretinography (2022 update)Documenta Ophthalmologica, 2022
- A novel method to reduce noise in electroretinography using skin electrodes: a study of noise level, inter-session variability, and reproducibilityInternational Ophthalmology, 2016
- Flash electroretinography: normative values with surface skin electrodes and no pupil dilation using a standard stimulation protocolDocumenta Ophthalmologica, 2007
- Principles and Practice of Clinical Electrophysiology of Vision2006
- Continuous and Reproducible Records of the Electrical Activity of the Human Retina.Experimental Biology and Medicine, 1941