Steps towards Smarter Solutions in Optometry and Ophthalmology—Inter-Device Agreement of Subjective Methods to Assess the Refractive Errors of the Eye
Open Access
- 13 July 2016
- journal article
- research article
- Published by MDPI AG in Healthcare
- Vol. 4 (3) , 41
Abstract
Purpose: To investigate the inter-device agreement and mean differences between a newly developed digital phoropter and the two standard methods (trial frame and manual phoropter). Methods: Refractive errors of two groups of participants were measured by two examiners (examiner 1 (E1): 36 subjects; examiner 2 (E2): 38 subjects). Refractive errors were assessed using a trial frame, a manual phoropter and a digital phoropter. Inter-device agreement regarding the measurement of refractive errors was analyzed for differences in terms of the power vector components (spherical equivalent (SE) and the cylindrical power vector components J0 and J45) between the used methods. Intraclass correlation coefficients (ICC’s) were calculated to evaluate correlations between the used methods. Results: Analyzing the variances between the three methods for SE, J0 and J45 using a two-way ANOVA showed no significant differences between the methods (SE: p = 0.13, J0: p = 0.58 and J45: p = 0.96) for examiner 1 and for examiner 2 (SE: p = 0.88, J0: p = 0.95 and J45: p = 1). Mean differences and ±95% Limits of Agreement for each pair of inter-device agreement regarding the SE for both examiners were as follows: Trial frame vs. digital phoropter: +0.10 D ± 0.56 D (E1) and +0.19 D ± 0.60 D (E2), manual phoropter vs. trial frame: −0.04 D ± 0.59 D (E1) and −0.12 D ± 0.49 D (E2) and for manual vs. digital phoropter: +0.06 D ± 0.65 D (E1) and +0.08 D ± 0.45 D (E2). ICCs revealed high correlations between all methods for both examiner (p < 0.001). The time to assess the subjective refraction was significantly smaller with the digital phoropter (examiner 1: p < 0.001; examiner 2: p < 0.001). Conclusion: “All used subjective methods show a good agreement between each other terms of ICC (>0.9). Assessing refractive errors using different subjective methods, results in similar mean differences and 95% limits of agreement, when compared to those reported in studies comparing subjective refraction non-cylcoplegic retinoscopy or autorefraction”.Keywords
This publication has 18 references indexed in Scilit:
- Spherical subjective refraction with a novel 3D virtual reality based systemJournal of Optometry, 2017
- Global Vision Impairment and Blindness Due to Uncorrected Refractive Error, 1990–2010Optometry and Vision Science, 2016
- Evaluation of the SVOneOptometry and Vision Science, 2015
- Zur Reproduzierbarkeit von RefraktionsbestimmungenDer Ophthalmologe, 2014
- Trial Frame Refraction versus Autorefraction among New Patients in a Low-Vision ClinicInvestigative Ophthalmology & Visual Science, 2013
- Validation of Near Eye Tool for Refractive Assessment (NETRA) – Pilot StudyJournal of Mobile Technology in Medicine, 2012
- Statistical methods for conducting agreement (comparison of clinical tests) and precision (repeatability or reproducibility) studies in optometry and ophthalmologyOphthalmic and Physiological Optics, 2011
- Prevalence of Refractive Error in the United States, 1999-2004Archives of Ophthalmology (1950), 2008
- Statistics Notes: Measurement error and correlation coefficientsBMJ, 1996
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986