Measurement of lung volume and ventilation distribution with an ultrasonic flow meter in healthy infants
Authors:
- A. SchiblerASA. Schibler
- G.L. HallGHG.L. Hall
- F. BusingerFBF. Businger
- B. ReinmannBRB. Reinmann
- J.H. WildhaberJWJ.H. Wildhaber
- M. CernelcMCM. Cernelc
- U. FreyUFU. Frey
Open Access
- 1 October 2002
- journal article
- research article
- Published by European Respiratory Society (ERS) in European Respiratory Journal
- Vol. 20 (4) , 912-918
Abstract
Small airway disease in infants is characterised by abnormal lung volume and uneven ventilation distribution. An inert tracer gas washin/washout technique using a pulsed ultrasonic flow meter is presented to measure functional residual capacity (FRC) and ventilation distribution in spontaneously breathing and unsedated infants.With a pulsed ultrasound sent through the main stream of the flow meter, flow, volume and MM of the breathing gas can be calculated. Sulphur hexafluoride was used as a tracer gas. In a mechanical lung model (volume range 53–188 mL) and in 12 healthy infants (aged 38.3±9.2 days; mean±sd) accuracy and reproducibility of the technique was assessed. Indices of ventilation distribution such as alveolar-based mean dilution number (AMDN) and pulmonary clearance delay (PCD) were calculated.Mean error of volume measurement in the lung model was 0.58% (coefficient of variance (CV) 1.3%). FRC was in the low predicted range for normal infants (18.0±2.0 mL·kg−1) and highly reproducible (5.5±1.7% intra-subject CV). AMDN was 1.63±0.15 and PCD was 52.9±11.1%.Measurement of functional residual capacity and ventilation distribution using a sulphur hexafluoride washin/washout and an ultrasonic flow meter proved to be highly accurate and reproducible in a lung model and in healthy, spontaneously breathing and unsedated infants.Keywords
This publication has 21 references indexed in Scilit:
- Positive end-expiratory pressure and ventilation inhomogeneity in mechanically ventilated childrenPediatric Critical Care Medicine, 2002
- The infant lung function model: a mechanical analogue to test infant lung function equipmentEuropean Respiratory Journal, 2001
- Specification for signal processing and data handling used for infant pulmonary function testing. ERS/ATS Task Force on Standards for Infant Respiratory Function Testing. European Respiratory Society/American Thoracic SocietyEuropean Respiratory Journal, 2000
- Specifications for equipment used for infant pulmonary function testingEuropean Respiratory Journal, 2000
- Moment ratio analysis of multiple breath nitrogen washout in infants with lung diseaseEuropean Respiratory Journal, 2000
- A computer-controlled research ventilator for small animals: design and evaluationIEEE Transactions on Biomedical Engineering, 1995
- Moment Analysis of a Multibreath Nitrogen Washout Based on an Alveolar Gas Dilution NumberAmerican Review of Respiratory Disease, 1991
- Measurement in Medicine: The Analysis of Method Comparison StudiesJournal of the Royal Statistical Society: Series D (The Statistician), 1983
- Lung washout during spontaneous breathing: Parameter estimation with a time-varying modelComputers and Biomedical Research, 1980
- LUNG FUNCTION STUDIES. VIII. ANALYSIS OF ALVEOLAR VENTILATION BY PULMONARY N2 CLEARANCE CURVES 12Journal of Clinical Investigation, 1952