Optimal design method of passive LCL filters for grid-connected inverters
Authors:
- 12 December 2016
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 237-242
Abstract
Imprudent selection of passive LCL filters parameters may result in worse filtering and excessive power losses. Existing designs methods are only able to provide a range for filters parameters, and therefore are not able to guarantee performance, without an extensive trial and adjustments process. To overcome this problem, a novel optimal design method of LCL filters, with several passive damping techniques, is proposed in this paper. The method is based on solving a constraint multi-objective optimisation problem, using genetic algorithm to obtain optimal passive LCL filters parameters. The goal of the optimisation method is to achieve high harmonic attenuation performance, reduce switching frequency ripples and minimise power loss. The design method is verified through simulation studies carried out on a three-phase grid-connected voltage source inverter (VSI) in a distributed generation (DG) system. The simulation results show that the new method can achieve higher ripple reduction and greater harmonic attenuation than existing methods. The paper also evaluates the performance of different passive LCL filter topologies.Keywords
This publication has 14 references indexed in Scilit:
- A Review of Passive Power Filters for Three-Phase Grid-Connected Voltage-Source ConvertersIEEE Journal of Emerging and Selected Topics in Power Electronics, 2015
- LLCL-Filtered Grid Converter With Improved Stability and RobustnessIEEE Transactions on Power Electronics, 2015
- Grid-Current-Feedback Active Damping for LCL Resonance in Grid-Connected Voltage-Source ConvertersIEEE Transactions on Power Electronics, 2015
- LCL Filter Design and Inductor Current Ripple Analysis for a Three-Level NPC Grid Interface ConverterIEEE Transactions on Power Electronics, 2014
- Grid-Filter Design for a Multimegawatt Medium-Voltage Voltage-Source InverterIEEE Transactions on Industrial Electronics, 2010
- Voltage‐Sourced Converters in Power Systems2010
- Design and Control of an LCL-Filter-Based Three-Phase Active RectifierIEEE Transactions on Industry Applications, 2005
- Step-by-step design procedure for a grid-connected three-phase PWM voltage source converterInternational Journal of Electronics, 2004
- Genetic Algorithm-Based Design of the Active Damping for an LCL-Filter Three-Phase Active RectifierIEEE Transactions on Power Electronics, 2004
- A Transfer Function Approach to Harmonic Filter DesignIEEE Industry Applications Magazine, 1997