Effect of Varying Slice Thickness on Coronary Calcium Scoring With Multislice Computed Tomography in Vitro and in Vivo
Authors:
- Georg MühlenbruchGMGeorg Mühlenbruch
- Christoph ThomasCTChristoph Thomas
- Joachim E. WildbergerJWJoachim E. Wildberger
- Ralf KoosRKRalf Koos
- Marco DasMDMarco Das
- Christian HohlCHChristian Hohl
- Marcus KatohMKMarcus Katoh
- Rolf W. GüntherRGRolf W. Günther
- Andreas H. MahnkenAMAndreas H. Mahnken
- 1 November 2005
- journal article
- research article
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 40 (11) , 695-699
Abstract
To compare coronary calcium scoring results (calcium volume, calcium mass, Agatston score, and number of lesions) of different slice thicknesses using a 16-slice CT (MSCT) scanner. A nonmoving anthropomorphic thorax phantom with calcium cylinders of different sizes and densities was scanned 30 times with repositioning applying a standardized retrospectively ECG-gated MSCT (SOMATOM Sensation 16; Siemens, Forchheim, Germany) scan protocol: collimation 12 × 0.75 mm, tube voltage 120 kV, effective tube current time-product 133 mAseff. Fifty patients (29 male; age 57.2 ± 8.4 years) underwent a nonenhanced scan applying the same scan protocol. Two image sets (effective slice thicknesses 3 mm and 1 mm) were reconstructed at 60% of the RR interval. Image noise was measured in both studies. Calcium volume, calcium mass and Agatston score were calculated using a commercially available software tool. Due to increased image noise in thinner slices, calcium scoring in all scans was performed applying a scoring threshold of 350 HU. In the phantom study, 1-mm slices showed significantly higher scoring results in respect to calcium volume (+8.2%), calcium mass (+12.5%), and Agatston score (+5.3%) (all P < 0.0001). In the patient study, 27 patients had coronary calcifications in 3-mm slices, and 31 patients had coronary calcifications in 1-mm slices. Thinner slices showed significantly higher scoring results in respect to volume (+47.1%), mass (+47.2%), and Agatston score (+29.7%) (all P < 0.0001). When comparing 3-mm and 1-mm slices in coronary calcium scoring in MSCT, thinner slices lead to significantly increased scoring results.Keywords
This publication has 29 references indexed in Scilit:
- Coronary calcifications in young patients with first, unheralded myocardial infarction: a risk factor matched analysis by electron beam tomographyHeart, 2003
- Coronary calcium and cardiovascular event risk: Evaluation by age- and sex-specific quartilesAmerican Heart Journal, 2002
- High coronary artery calcium scores pose an extremely elevated risk for hard eventsJACC, 2002
- Coronary Artery Calcium MeasurementAmerican Journal of Roentgenology, 2001
- Evaluation of Subsecond Gated Helical CT for Quantification of Coronary Artery Calcium and Comparison with Electron Beam CTAmerican Journal of Roentgenology, 2000
- Electron Beam Computed Tomographic Coronary Calcium Scanning: A Review and Guidelines for Use in Asymptomatic PersonsMayo Clinic Proceedings, 1999
- Comparison of electron beam computed tomography scanning and conventional risk factor assessment for the prediction of angiographic coronary artery diseaseJACC, 1998
- Electron Beam Computed Tomographic Coronary Calcium Score Cutpoints and Severity of Associated Angiographic Lumen StenosisJACC, 1997
- Coronary Artery Calcium Area by Electron-Beam Computed Tomography and Coronary Atherosclerotic Plaque AreaCirculation, 1995
- Quantification of coronary artery calcium using ultrafast computed tomographyJACC, 1990