Pseudocontamination of blood components with Burkholderia cepacia during quality controls
Authors:
- 6 June 2005
- journal article
- Published by Wiley in Transfusion Medicine
- Vol. 15 (3) , 241-242
Abstract
summary. We report on a pseudooutbreak of Burkholderia cepacia because of the use of a contaminated disinfectant during quality controls in a university blood bank. No septic reactions associated with transfusions had been reported in patients over the last 6 months. Analysis of the individual quality control procedures showed that a disinfectant based on a quaternary ammonium compound (QAC) had been used in order to disinfect the rubber stopper of the blood culture bottle. B. cepacia was found in a sample taken from this disinfectant, which was prepared with concentrate and tap water according to the manufacturer's instructions. The four isolates (one in disinfectant and three in blood components) were found to be identical in their biochemical reactions and resistance patterns. QAC‐based disinfectants are not efficacious against a part of the spectrum of gram‐negatives and are therefore inadequate. After introduction of an alcohol‐based preparation, no more cases of B. cepacia contamination have been identified.Keywords
This publication has 11 references indexed in Scilit:
- Bacterial contamination of blood components due to Burkholderia cepacia contamination from clorhexidine bottlesVox Sanguinis, 2002
- An Outbreak of Burkholderia cepacia Lower Respiratory Tract Infection Associated with Contaminated Albuterol Nebulization SolutionInfection Control & Hospital Epidemiology, 1996
- An Outbreak of Burkholderia cepacia Lower Respiratory Tract Infection Associated With Contaminated Albuterol Nebulization SolutionInfection Control & Hospital Epidemiology, 1996
- Nosocomial Burkholderia cepacia Outbreaks and Pseudo-OutbreaksInfection Control & Hospital Epidemiology, 1996
- Microbial contamination of antiseptics and disinfectantsAmerican Journal of Infection Control, 1996
- Nosocomial Outbreak of Pseudomonas cepacia Associated with Contamination of Reusable Electronic Ventilator Temperature ProbesInfection Control & Hospital Epidemiology, 1993
- Nosocomial Outbreak of Pseudomonas cepacia Associated with Contamination of Reusable Electronic Ventilator Temperature ProbesInfection Control & Hospital Epidemiology, 1993
- Infections and Pseudoinfections Due to Povidone-Iodine Solution Contaminated with Pseudomonas cepaciaClinical Infectious Diseases, 1992
- Nosocomial PseudobacteremiaJAMA, 1976
- Nosocomial pseudobacteremia. Positive blood cultures due to contaminated benzalkonium antisepticJAMA, 1976