Multiplexed and extraction-free amplification for simplified SARS-CoV-2 RT-PCR tests
Authors:
- Samantha A. ByrnesSBSamantha A. Byrnes
- Ryan GallagherRGRyan Gallagher
- Amy SteadmanASAmy Steadman
- Crissa BennettCBCrissa Bennett
- Rafael RiveraRRRafael Rivera
- Corrie OrtegaCOCorrie Ortega
- S. Timothy MotleySMS. Timothy Motley
- Paras JainPJParas Jain
- Bernhard H. WeiglBWBernhard H. Weigl
- John T. ConnellyJCJohn T. Connelly
Preprint
Abstract
The rapid onset of the global COVID-19 pandemic has led to multiple challenges for accurately diagnosing the infection. One of the main bottlenecks for COVID-19 detection is reagent and material shortages for sample collection, preservation, and purification prior to testing. Currently, most authorized diagnostic tests require RNA extraction from patient samples and detection by reverse transcription polymerase chain reaction (RT-PCR). However, RNA purification is expensive, time consuming, and requires technical expertise to perform. Additionally, there have been reported shortages of the RNA purification kits needed for most tests. With these challenges in mind, we report on extraction-free amplification of SARS-CoV-2 RNA directly from patient samples. In addition, we have developed a multiplex RT-PCR using the CDC singleplex targets. This multiplex has a limit of detection of 2 copies/μL. We have demonstrated these improvements to the current diagnostic workflow, which reduce complexity and cost, minimize reagent usage, expedite time to results, and increase testing capacity.Keywords
All Related Versions
- Published version: Analytical Chemistry, 93 (9), 4160.
This publication has 7 references indexed in Scilit:
- Massive and rapid COVID-19 testing is feasible by extraction-free SARS-CoV-2 RT-PCRNature Communications, 2020
- Triplex Real-Time RT-PCR for Severe Acute Respiratory Syndrome Coronavirus 2Emerging Infectious Diseases, 2020
- A new coronavirus associated with human respiratory disease in ChinaNature, 2020
- Development of a direct reverse-transcription quantitative PCR (dirRT-qPCR) assay for clinical Zika diagnosisInternational Journal of Infectious Diseases, 2019
- The MIQE Guidelines: Minimum Information for Publication of Quantitative Real-Time PCR ExperimentsClinical Chemistry, 2009
- Mutants of Taq DNA polymerase resistant to PCR inhibitors allow DNA amplification from whole blood and crude soil samplesNucleic Acids Research, 2009
- AutoDimer: a screening tool for primer-dimer and hairpin structuresBioTechniques, 2004