Accuracy of Intraoperative Mechanical Axis Alignment to Long-Leg Radiographs following Robotic-Arm–Assisted Unicompartmental Knee Arthroplasty
- 3 February 2022
- journal article
- research article
- Published by Georg Thieme Verlag KG in The Journal of Knee Surgery
- Vol. 36 (07) , 752-758
Abstract
Improper alignment and implant positioning following unicompartmental knee arthroplasty (UKA) has been shown to lead to postoperative pain and increase the incidence of revision procedures. The use of robotic-arm assistance for UKA (RAUKA) has become an area of interest to help overcome these challenges. The accuracy of intraoperative alignment compared with standing long-leg X-rays postoperatively following medial RAUKA has been in question. Therefore, the purpose of this study was to (1) determine final mean intraoperative coronal alignment in extension utilizing an image based intraoperative navigation system, and (2) compare final intraoperative alignment to 6-week weight-bearing (WB) long-leg X-rays. Patients who underwent RAUKA for medial compartmental osteoarthritis were identified from January 1, 2018, to August 31, 2019, through our institution's joint registry. The query yielded 136 (72 right and 64 left) patients with a mean age of 72.02 years and mean body mass index (BMI) of 28.65 kg/m2 who underwent RAUKA. Final intraoperative alignment was compared with WB long leg X-rays 6 weeks postoperatively by measuring the mechanical alignment. Statistical analysis was primarily descriptive. Pearson's correlation coefficient was used to determine the relationship between intraoperative alignment to 6-week alignment. A p-value of <0.05 was considered statistically significant. Mean intraoperative coronal alignment after resections and trialing was 4.39 varus ± 2.40 degrees for the right knee, and 4.81 varus ± 2.29 degrees for the left knee. WB long-leg X-rays 6 weeks postoperatively demonstrated mechanical axis alignment for the right and left knees to be 3.01 varus ± 2.10 and 3.7 varus ± 2.38 degrees, respectively. This resulted in a change in alignment of 1.36 ± 1.76 and 1.12 ± 1.84 degrees for the right and left knees, respectively (p < 0.05). Pearson's correlation coefficient demonstrated a correlation of 0.69 between intraoperative to long-leg-X-ray alignment. RAUKA demonstrates excellent consistency when comparing postoperative WB long-leg X-rays to final intraoperative image-based non-WB alignment. Received: 23 May 2021 Accepted: 09 December 2021 Publication Date: 03 February 2022 (online) © 2022. Thieme. All rights reserved. Thieme Medical Publishers, Inc. 333 Seventh Avenue, 18th Floor, New York, NY 10001, USAKeywords
This publication has 33 references indexed in Scilit:
- Causes of revision following Oxford phase 3 unicompartmental knee arthroplastyKnee Surgery, Sports Traumatology, Arthroscopy, 2013
- The long leg radiograph is a reliable method of assessing alignment when compared to computer-assisted navigation and computer tomographyThe Knee, 2013
- Oxford phase 3 unicompartmental knee replacement in Korean patientsThe Journal of Bone and Joint Surgery. British volume, 2012
- Minimally invasive Oxford phase 3 unicompartmental knee replacementThe Journal of Bone and Joint Surgery. British volume, 2011
- Robot-Assisted Unicompartmental Knee ArthroplastyThe Journal of Arthroplasty, 2010
- Robotic Arm-assisted UKA Improves Tibial Component Alignment: A Pilot StudyClinical Orthopaedics and Related Research, 2010
- Incidence and Reasons for Reoperation after Minimally Invasive Unicompartmental Knee ArthroplastyThe Journal of Arthroplasty, 2006
- Patient, Implant, and Alignment Factors Associated With Revision of Medial Compartment Unicondylar ArthroplastyThe Journal of Arthroplasty, 2006
- Hands-on robotic unicompartmental knee replacementThe Journal of Bone and Joint Surgery. British volume, 2006
- Limb alignment in computer-assisted minimally-invasive unicompartmental knee replacementThe Journal of Bone and Joint Surgery. British volume, 2006