Simplified quantification of labile proton concentration‐weighted chemical exchange rate (kws) with RF saturation time dependent ratiometric analysis (QUESTRA): Normalization of relaxation and RF irradiation spillover effects for improved quantitative chemical exchange saturation transfer (CEST) MRI
Open Access
- 12 August 2011
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 67 (4) , 936-942
Abstract
Chemical exchange saturation transfer MRI is an emerging imaging technique capable of detecting dilute proteins/peptides and microenvironmental properties, with promising in vivo applications. However, chemical exchange saturation transfer MRI contrast is complex, varying not only with the labile proton concentration and exchange rate, but also with experimental conditions such as field strength and radiofrequency (RF) irradiation scheme. Furthermore, the optimal RF irradiation power depends on the exchange rate, which must be estimated in order to optimize the chemical exchange saturation transfer MRI experiments. Although methods including numerical fitting with modified Bloch‐McConnell equations, quantification of exchange rate with RF saturation time and power (QUEST and QUESP), have been proposed to address this relationship, they require multiple‐parameter non‐linear fitting and accurate relaxation measurement. Our work extended the QUEST algorithm with ratiometric analysis (QUESTRA) that normalizes the magnetization transfer ratio at labile and reference frequencies, which effectively eliminates the confounding relaxation and RF spillover effects. Specifically, the QUESTRA contrast approaches its steady state mono‐exponentially at a rate determined by the reverse exchange rate (kws), with little dependence on bulk water T1, T2, RF power and chemical shift. The proposed algorithm was confirmed numerically, and validated experimentally using a tissue‐like phantom of serially titrated pH compartments. Magn Reson Med, 2011.Keywords
Funding Information
- AHA/SDG (0835384N)
- NIH/NIBIB (1K01EB009771)
- NIH/NINDS (1R21NS061119)
- NIH/NCRR (P41RR14075)
- Genzyme-Partners Healthcare Initiative Translational Grant
This publication has 42 references indexed in Scilit:
- Simulation and optimization of pulsed radio frequency irradiation scheme for chemical exchange saturation transfer (CEST) MRI—demonstration of pH‐weighted pulsed‐amide proton CEST MRI in an animal model of acute cerebral ischemiaMagnetic Resonance in Medicine, 2011
- Spin-locking versus chemical exchange saturation transfer MRI for investigating chemical exchange process between water and labile metabolite protonsMagnetic Resonance in Medicine, 2010
- Fast multislice pH‐weighted chemical exchange saturation transfer (CEST) MRI with Unevenly segmented RF irradiationMagnetic Resonance in Medicine, 2010
- Simplified and scalable numerical solution for describing multi-pool chemical exchange saturation transfer (CEST) MRI contrastJournal of Magnetic Resonance, 2010
- A concentration-independent method to measure exchange rates in PARACEST agentsMagnetic Resonance in Medicine, 2010
- Simultaneous determination of labile proton concentration and exchange rate utilizing optimal RF power: Radio frequency power (RFP) dependence of chemical exchange saturation transfer (CEST) MRIJournal of Magnetic Resonance, 2010
- Water saturation shift referencing (WASSR) for chemical exchange saturation transfer (CEST) experimentsMagnetic Resonance in Medicine, 2009
- Investigation of optimizing and translating pH‐sensitive pulsed‐chemical exchange saturation transfer (CEST) imaging to a 3T clinical scannerMagnetic Resonance in Medicine, 2008
- New “multicolor” polypeptide diamagnetic chemical exchange saturation transfer (DIACEST) contrast agents for MRIMagnetic Resonance in Medicine, 2008
- Amide proton transfer imaging of 9L gliosarcoma and human glioblastoma xenograftsNMR in Biomedicine, 2008