The use of high-frequency short bipolar pulses in cisplatin electrochemotherapy in vitro
Open Access
- 1 June 2019
- journal article
- research article
- Published by Walter de Gruyter GmbH in Radiology and Oncology
- Vol. 53 (2) , 194-205
Abstract
Background: In electrochemotherapy (ECT), chemotherapeutics are first administered, followed by short 100 μs monopolar pulses. However, these pulses cause pain and muscle contractions. It is thus necessary to administer muscle relaxants, general anesthesia and synchronize pulses with the heart rhythm of the patient, which makes the treatment more complex. It was suggested in ablation with irreversible electroporation, that bursts of short high-frequency bipolar pulses could alleviate these problems. Therefore, we designed our study to verify if it is possible to use high-frequency bipolar pulses (HF-EP pulses) in electrochemotherapy. Materials and methods: We performed in vitro experiments on mouse skin melanoma (B16-F1) cells by adding 1–330 μM cisplatin and delivering either (a) eight 100 μs long monopolar pulses, 0.4–1.2 kV/cm, 1 Hz (ECT pulses) or (b) eight bursts at 1 Hz, consisting of 50 bipolar pulses. One bipolar pulse consisted of a series of 1 μs long positive and 1 μs long negative pulse (0.5–5 kV/cm) with a 1 μs delay in-between. Results: With both types of pulses, the combination of electric pulses and cisplatin was more efficient in killing cells than cisplatin or electric pulses only. However, we needed to apply a higher electric field in HF-EP (3 kV/cm) than in ECT (1.2 kV/cm) to obtain comparable cytotoxicity. Conclusions: It is possible to use HF-EP in electrochemotherapy; however, at the expense of applying higher electric fields than in classical ECT. The results obtained, nevertheless, offer an evidence that HF-EP could be used in electrochemotherapy with potentially alleviated muscle contractions and pain.Keywords
This publication has 67 references indexed in Scilit:
- High-frequency irreversible electroporation (H-FIRE) for non-thermal ablation without muscle contractionBioMedical Engineering OnLine, 2011
- Irreversible ElectroporationAnesthesia & Analgesia, 2010
- Enhanced cytotoxicity of bleomycin and cisplatin after electroporation in murine colorectal carcinoma cellsRadiology and Oncology, 2009
- Kinetics of Transmembrane Transport of Small Molecules into Electropermeabilized CellsBiophysical Journal, 2008
- The effect of electroporation pulses on functioning of the heartMedical & Biological Engineering & Computing, 2008
- Analytical and numerical quantification and comparison of the local electric field in the tissue for different electrode configurationsBioMedical Engineering OnLine, 2007
- Strength-Duration Curve for an Electrically Excitable Tissue Extended Down to Near 1 NanosecondIEEE Transactions on Plasma Science, 2004
- Cell membrane electropermeabilization by symmetrical bipolar rectangular pulsesBioelectrochemistry, 2001
- Effect of Electric-Field Intensity on Electropermeabilization and Electrosensitmty of Various Tumor-Cell LinesIn VitroElectro- and Magnetobiology, 1998
- Bleomycin: Revival of an old drugGeneral Pharmacology: The Vascular System, 1996