Research on Fuzzy Active Disturbance Rejection Control of LCL Grid-Connected Inverter Based on Passivity-Based Control in Weak Grid
Open Access
- 13 April 2023
- journal article
- research article
- Published by MDPI AG in Electronics
- Vol. 12 (8) , 1847
Abstract
In response to the problems of impedance variation and rich background harmonics in the weak grid environment of traditional LCL grid-connected inverters, which cause distortion of the grid-connected current and reduce the stability of the entire grid-connected system, this paper proposes a passive fuzzy-active disturbance rejection control strategy. Firstly, passivity-based control (PBC) is introduced into the grid-connected inverter system to ensure the global stability of the entire system. Secondly, in order to solve the problem of difficult selection of inverter-side current, active disturbance rejection control (ADRC) is used to directly track the grid-connected current, avoiding the tracking error of AC signal and suppressing the interference of background harmonics of grid voltage. The combination of fuzzy control and ADRC simplifies the system parameter tuning process, and the FUZZY-ADRC grid-connected current outer loop and PBC inductance current inner loop are combined to form a multi-loop control system. Finally, simulation comparison verifies that the proposed control strategy can effectively suppress the harmonics of grid-connected current, improve the quality of grid-connected current, and enhance the stability of the entire grid-connected system in a weak grid environment.Keywords
Funding Information
- Innovation Fund for Industry University Research in Chinese Universities (2021ITA05025, 61473116)
- National Natural Science Foundation of China (2021ITA05025, 61473116)
This publication has 18 references indexed in Scilit:
- A novel harmonic impedance compensator based on POHMR-type RC under gird voltage distortionInternational Journal of Electrical Power & Energy Systems, 2021
- A Gray-Box Hierarchical Oscillatory Instability Source Identification Method of Multiple-Inverter-Fed Power SystemsIEEE Journal of Emerging and Selected Topics in Power Electronics, 2020
- Small-Signal Disturbance Compensation Control for LCL-Type Grid-Connected Converter in Weak GridIEEE Transactions on Industry Applications, 2020
- Passivity-Based Stabilization of LCL-Type Grid-Connected Inverters via a General Admittance ModelIEEE Transactions on Power Electronics, 2019
- Passivity-Based Design of Plug-and-Play Current-Controlled Grid-Connected InvertersIEEE Transactions on Power Electronics, 2019
- Linear ADRC direct current control of grid‐connected inverter with LCL filter for both active damping and grid voltage induced current distortion suppressionIET Power Electronics, 2018
- Damping techniques for grid-connected voltage source converters based on LCL filter: An overviewRenewable and Sustainable Energy Reviews, 2018
- Control of Single-Phase Grid-Connected Converters with LCL Filters Using Recurrent Neural Network and Conventional Control MethodsIEEE Transactions on Power Electronics, 2015
- Composite Nonlinear Feedback Control and Stability Analysis of a Grid-Connected Voltage Source Inverter With $LCL$ FilterIEEE Transactions on Industrial Electronics, 2012
- Basic Criteria in Designing LCL Filters for Grid Connected Converters2006