Comparative Performance of Reagents and Platforms for Quantitation of Cytomegalovirus DNA by Digital PCR
Open Access
- 1 October 2016
- journal article
- research article
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 54 (10) , 2602-2608
Abstract
A potential benefit of digital PCR is a reduction in result variability across assays and platforms. Three sets of PCR reagents were tested on two digital PCR systems (Bio-Rad and RainDance), using three different sets of PCR reagents for quantitation of cytomegalovirus (CMV). Both commercial quantitative viral standards and 16 patient samples ( n = 16) were tested. Quantitative accuracy (compared to nominal values) and variability were determined based on viral standard testing results. Quantitative correlation and variability were assessed with pairwise comparisons across all reagent-platform combinations for clinical plasma sample results. The three reagent sets, when used to assay quantitative standards on the Bio-Rad system, all showed a high degree of accuracy, low variability, and close agreement with one another. When used on the RainDance system, one of the three reagent sets appeared to have a much better correlation to nominal values than did the other two. Quantitative results for patient samples showed good correlation in most pairwise comparisons, with some showing poorer correlations when testing samples with low viral loads. Digital PCR is a robust method for measuring CMV viral load. Some degree of result variation may be seen, depending on platform and reagents used; this variation appears to be greater in samples with low viral load values.Keywords
This publication has 20 references indexed in Scilit:
- Impact of variance components on reliability of absolute quantification using digital PCRBMC Bioinformatics, 2014
- Clinical Utility of Viral Load in Management of Cytomegalovirus Infection after Solid Organ TransplantationClinical Microbiology Reviews, 2013
- Methods for Applying Accurate Digital PCR Analysis on Low Copy DNA SamplesPLOS ONE, 2013
- Factors Contributing to Variability of Quantitative Viral PCR Results in Proficiency Testing Samples: a Multivariate AnalysisJournal of Clinical Microbiology, 2012
- High-Throughput Droplet Digital PCR System for Absolute Quantitation of DNA Copy NumberAnalytical Chemistry, 2011
- Molecular diagnostics: harmonization through reference materials, documentary standards and proficiency testingExpert Review of Molecular Diagnostics, 2011
- EBV viral load detection in clinical virologyJournal of Clinical Virology, 2010
- International Standards and Reference Materials for Quantitative Molecular Infectious Disease TestingThe Journal of Molecular Diagnostics, 2010
- Marked Variability of BK Virus Load Measurement Using Quantitative Real-Time PCR among Commonly Used AssaysJournal of Clinical Microbiology, 2008
- Digital PCRProceedings of the National Academy of Sciences, 1999