In-vivo high resolution three-dimensional MRI studies of rat joints at 7 T
- 22 December 2003
- journal article
- research article
- Published by Wiley in NMR in Biomedicine
- Vol. 16 (8) , 484-493
Abstract
It is important to obtain high resolution images of joints for the study of disease, especially in rodent experimental models. We optimized 1H magnetic resonance imaging three‐dimensional sequences at 7 T, with lipid signal suppression, and T1 and T2 measurements for in‐vivo experiments on rat joints, in order to assess the effectiveness of high‐field MRI. The method was validated by applying it to the early diagnosis of arthritis. We studied the progress of rheumatoid arthritis in an arthritic rat model. We observed the rats' knees for 21 days after inducing arthritis. The images acquired over one hour had a high resolution of 1.75 × 10−3 mm3, (105 × 105 × 145 μm3) which allowed us to spot the early stages of joint degeneration, such as bone erosion, and to observe an apparent ‘MRI’ loss of cartilage thickness, attributed to dehydration of the cartilage tissue. The MR images obtained during the early stages of rheumatoid arthritis enabled us to study joint changes accurately before any histological signs of attack were visible. Copyright © 2003 John Wiley & Sons, Ltd.Keywords
This publication has 43 references indexed in Scilit:
- Elastic registration of 3D cartilage surfaces from MR image data for detecting local changes in cartilage thicknessMagnetic Resonance in Medicine, 2000
- The role of relaxation times in monitoring proteoglycan depletion in articular cartilageJournal of Magnetic Resonance Imaging, 1999
- Detection of knee hyaline cartilage defects using fat-suppressed three-dimensional spoiled gradient-echo MR imaging: comparison with standard MR imaging and correlation with arthroscopy.American Journal of Roentgenology, 1995
- Chondromalacia patellae: fat-suppressed MR imaging.Radiology, 1994
- Fat-suppressed spoiled GRASS imaging of knee hyaline cartilage: technique optimization and comparison with conventional MR imaging.American Journal of Roentgenology, 1994
- Quantification of articular cartilage in the knee with pulsed saturation transfer subtraction and fat-suppressed MR imaging: optimization and validation.Radiology, 1994
- MR imaging of the arthritic knee: improved discrimination of cartilage, synovium, and effusion with pulsed saturation transfer and fat-suppressed T1-weighted sequences.Radiology, 1994
- Combined chemical-shift and phase-selective imaging for fat suppression: theory and initial clinical experience.Radiology, 1991
- MR Fat Suppression Technique in the Evaluation of Normal Structures of the KneeJournal of Computer Assisted Tomography, 1989
- Gradient reversal technique and its applications to chemical-shift-related NMR imagingMagnetic Resonance in Medicine, 1987