Electrochemical determination of lead in human blood serum and urine by anodic stripping voltammetry using glassy carbon electrodes covered with Ag–Hg and Ag–Bi bimetallic nanoparticles
- 5 July 2018
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 10 (34) , 4114-4121
Abstract
The evaluation and application of glassy carbon electrodes modified with bimetallic nanoparticle deposits of Ag–Hg and Ag–Bi for determination of Pb(II) is described. Deposition of the nanostructured bimetallic combinations on top of the glassy carbon (GC) substrate, previously covered with a Nafion (Nf) film, resulted in electrodes with substantially enlarged hydrogen evolution over-voltage. As indicated by scanning electron microscopy and atomic force microscopy images, most of the deposited nanoparticles, with an average size of 150 nm, were uniformly dispersed inside the Nafion net while a smaller amount remained on top of the embedded ones. Sensitivity tests of the AgBiNpNf/GC modified electrode produced a detection limit (DL), based on the 3s criterion, of 0.66 μg L−1 and 0.24 μg L−1 for the AgHgNpNf/GC electrode. Accuracy was assessed by comparison with quantification of Pb(II) in human blood serum and urine samples analyzed by atomic absorption spectrometry, using a continuous source high resolution atomic absorption spectrometer.Keywords
Funding Information
- Universidad Simón Bolívar
- Secretaría de Educación Superior, Ciencia, Tecnología e Innovación de la República del Ecuador
This publication has 32 references indexed in Scilit:
- Determination of trace heavy metals in herbs by sequential injection analysis-anodic stripping voltammetry using screen-printed carbon nanotubes electrodesAnalytica Chimica Acta, 2010
- Advanced Use of Nanobismuth/Nafion Electrode for Trace Analyses of Zinc, Cadmium, and LeadJournal of the Electrochemical Society, 2010
- Electrochemical Properties and Application of Mixed Silver‐Bismuth ElectrodesElectroanalysis, 2005
- Perfluorinated anion-exchange polymer mercury film electrode for anodic stripping voltammetric determination of zinc(II): effect of model organic compoundsAnalytica Chimica Acta, 2002
- Poly(ester sulphonic acid) coated mercury thin film electrodes: characterization and application in batch injection analysis stripping voltammetry of heavy metal ionsTalanta, 2000
- Comparative Study of Conventional and Cellulose Acetate-Coated Mercury Film Electrodes for Speciation of Lead in the Presence of Humic AcidElectroanalysis, 2000
- Determination of Lead and Copper in Wine by Anodic Stripping Voltammetry With Mercury Microelectrodes: Assessment of the Influence of Sample Pretreatment ProceduresThe Analyst, 1997
- Mercury film electrodes coated with negatively charged polymer films in speciation studies of trace amounts of leadElectroanalysis, 1996
- Cyclic voltammetry of dental amalgamsDental Materials, 1996
- Study of the Initial Stages of Anodic Oxidation of Polycrystalline Silver in KOH SolutionsJournal of the Electrochemical Society, 1984