Biomechanics and finite element analysis comparing posterior T-plates with LCP for fixation of posterolateral tibial plate fractures
Open Access
- 7 December 2023
- journal article
- research article
- Published by Frontiers Media SA in Frontiers in Bioengineering and Biotechnology
- Vol. 11, 1286993
Abstract
Objective: The treatment for posterolateral tibial plateau fractures (PTPF) have been subjects of controversy. We conducted a study to improve the fixation of PTPF through a lateral approach.Methods: We utilized 40 synthetic tibias and categorized the fracture models into five groups based on the locking compression plate (LCP) and T-distal radius plate (TPP) via various forms of fixation with screws through the posterolateral (PL) fracture fragments. I: Two-screw fixation using two locking screws (LPTL). Ⅱ: Two-screw fixation with both variable angle locking screws (LPTV). Ⅲ: One-screw fixation with one locking screw (LPOL). Ⅳ: One-screw fixation with one locking screw and two anteroposterior lag screws (LPOLTL). Ⅴ: a distal radius plate with three locking screws (TPP). Biomechanical tests were conducted to observe the axial compression displacement of the PL fracture fragments at force levels of 250 N, 500 N, and 750 N, as well as to determine the failure load and the axial stiffness for each respective group.Results: Under a 750 N load condition, the displacements within the five experimental groups exhibited the following trend: Ⅴ < Ⅱ < Ⅰ< Ⅳ < Ⅲ. However, there were no significant differences between Group V and Group II, Group I and Group IV (p > 0.05), and only Group Ⅲ demonstrated a displacement exceeding 3 mm. The failure load and the axial stiffness exhibited the same trend. Conversely, statistical significance was identified among the remaining group compared with Group Ⅲ (p < 0.05). Regarding the finite element analysis, the maximum displacements for the five models under the load of 750 N exhibited the following trend: Ⅴ < Ⅱ < Ⅰ< Ⅳ < Ⅲ. The following trends were observed in maximum von Mises stresses for these models under the load of 750 N: Ⅴ < Ⅱ < Ⅳ< Ⅰ < Ⅲ.Conclusion: It is crucial to address the inadequate mechanical strength associated with single screw fixation of LCP for fixing PL fractures in a clinical setting. The biomechanical strength of two-screw fixation surpasses that of single-screw fixation. Introducing variable-angle screws can further enhance the fixation range. Furthermore, the addition of two lag screws threaded from anterior to posterior can compensate the mechanical stability, when PL fracture is fixed with single screw in clinic.Keywords
This publication has 46 references indexed in Scilit:
- A biomechanical study comparing polyaxial locking screw mechanismsInjury, 2013
- Biomechanical analysis of four different fixations for the posterolateral shearing tibial plateau fractureThe Knee, 2012
- Finite element modeling of a 3D coupled foot–boot modelMedical Engineering & Physics, 2011
- Challenges in modeling total knee arthroplasty and total hip replacementProcedia IUTAM, 2011
- Incidence and Morphology of the Posteromedial Fragment in Bicondylar Tibial Plateau FracturesJournal of Orthopaedic Trauma, 2009
- The posterolateral shearing tibial plateau fracture:The Knee, 2008
- Operative Treatment of 109 Tibial Plateau Fractures: Five- to 27-Year Follow-up ResultsJournal of Orthopaedic Trauma, 2007
- Tibio‐femoral loading during human gait and stair climbingJournal of Orthopaedic Research, 2004
- Tibio-femoral loading during human gait and stair climbingJournal of Orthopaedic Research, 2004
- Friction properties of the interface between porous‐surfaced metals and tibial cancellous boneJournal of Biomedical Materials Research, 1990