Blind deconvolution of 3D fluorescence microscopy using depth-variant asymmetric PSF
Authors:
- 8 April 2016
- journal article
- research article
- Published by Wiley in Microscopy Research and Technique
- Vol. 79 (6) , 480-494
Abstract
The 3D wide-field fluorescence microscopy suffers from depth-variant asymmetric blur. The depth-variance and axial asymmetry are due to refractive index mismatch between the immersion and the specimen layer. The radial asymmetry is due to lens imperfections and local refractive index inhomogeneities in the specimen. To obtain the PSF that has these characteristics, there were PSF premeasurement trials. However, they are useless since imaging conditions such as camera position and refractive index of the specimen are changed between the premeasurement and actual imaging. In this article, we focus on removing unknown depth-variant asymmetric blur in such an optical system under the assumption of refractive index homogeneities in the specimen. We propose finding few parameters in the mathematical PSF model from observed images in which the PSF model has a depth-variant asymmetric shape. After generating an initial PSF from the analysis of intensities in the observed image, the parameters are estimated based on a maximum likelihood estimator. Using the estimated PSF, we implement an accelerated GEM algorithm for image deconvolution. Deconvolution result shows the superiority of our algorithm in terms of accuracy, which quantitatively evaluated by FWHM, relative contrast, standard deviation values of intensity peaks and FWHM. Microsc. Res. Tech. 79:480–494, 2016.Keywords
This publication has 23 references indexed in Scilit:
- Robust Statistics2011
- Phase‐retrieved pupil functions in wide‐field fluorescence microscopyJournal of Microscopy, 2004
- Principles of Optics1999
- Acceleration of iterative image restoration algorithmsApplied Optics, 1997
- Fast regularization technique for expectation maximization algorithm for optical sectioning microscopy1996
- Superresolution Three-Dimensional Images of Fluorescence in Cells with Minimal Light ExposureScience, 1995
- Maximum a posteriori estimation with Good’s roughness for three-dimensional optical-sectioning microscopyJournal of the Optical Society of America A, 1993
- Blind deconvolution of quantum-limited incoherent imagery: maximum-likelihood approachJournal of the Optical Society of America A, 1992
- Methods for choosing the regularization parameter and estimating the noise variance in image restoration and their relationIEEE Transactions on Image Processing, 1992
- Experimental test of an analytical model of aberration in an oil-immersion objective lens used in three-dimensional light microscopyJournal of the Optical Society of America A, 1992