Abstract
Objectives: This study attempts to explore a novel peripheral lung stereotactic body radiotherapy (SBRT) planning technique that can balance the pros and cons of three‐dimensional conformal radiotherapy (CRT) and intensity‐modulated radiation therapy (IMRT) / volumetric modulated arc therapy (VMAT).Methods: Treatment plans were retrospectively designed based on CRT, IMRT, VMAT, and the proposed CRT‐IMRT‐combined (Co‐CRIM) techniques using Pinnacle treatment planning system (TPS) for 20 peripheral lung cancer patients. Co‐CRIM used an inverse optimization algorithm available in Pinnacle TPS. To develop a Co‐CRIM plan, the number of segments in each field was limited to one, the minimum segment area was set to the internal target volume (ITV), and the minimum monitor units (MU) of the segment was the quotient of fractional dose divided by twice the number of total fields. The performance of Co‐CRIM was then compared with other techniques.Results: For conformity index (CI), Co‐CRIM performed comparably to IMRT/VMAT but better than CRT. For gradient index (GI), Co‐CRIM was similar to IMRT/VMAT or CRT. For heterogeneity index (HI), Co‐CRIM was comparable to IMRT/VMAT, higher than CRT. The dosimetric results of spinal cord and lung with Co‐CRIM were better than CRT, comparable to IMRT, but inferior to VMAT. The MU resulted from Co‐CRIM was lower than IMRT/VMAT but higher than CRT. For plan verification γ passing rate, Co‐CRIM was higher than IMRT/VMAT, comparable to CRT. For planning time, Co‐CRIM was shorter than CRT or VMAT but similar to IMRT.Conclusions: The proposed Co‐CRIM technique on Pinnacle TPS is an effective planning technique for peripheral lung SBRT.Keywords
Funding Information
- Shanghai Chest Hospital (2019YNJCM05)
This publication has 31 references indexed in Scilit:
- Stereotactic Body Radiotherapy (SBRT) for Operable Stage I Non–Small-Cell Lung Cancer: Can SBRT Be Comparable to Surgery?International Journal of Radiation Oncology - Biology - Physics (IJROBP), 2011
- Volumetric-Modulated Arc Therapy for Stereotactic Body Radiotherapy of Lung Tumors: A Comparison With Intensity-Modulated Radiotherapy TechniquesInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2011
- Volumetric modulated arc planning for lung stereotactic body radiotherapy using conventional and unflattened photon beams: a dosimetric comparison with 3D techniqueRadiation Oncology, 2011
- Stereotactic radiotherapy for peripheral lung tumors: A comparison of volumetric modulated arc therapy with 3 other delivery techniquesRadiotherapy and Oncology, 2010
- Stereotactic body radiation therapy: The report of AAPM Task Group 101Medical Physics, 2010
- Volumetric modulated arc therapy for delivery of hypofractionated stereotactic lung radiotherapy: A dosimetric and treatment efficiency analysisRadiotherapy and Oncology, 2010
- Chest Wall Volume Receiving >30 Gy Predicts Risk of Severe Pain and/or Rib Fracture After Lung Stereotactic Body RadiotherapyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2010
- Hybrid IMRT for Treatment of Cancers of the Lung and EsophagusInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2008
- Hypofractionated Stereotactic Radiotherapy (HypoFXSRT) for Stage I Non-small Cell Lung Cancer: Updated Results of 257 Patients in a Japanese Multi-institutional StudyJournal of Thoracic Oncology, 2007
- A conformation number to quantify the degree of conformality in brachytherapy and external beam irradiation: Application to the prostateInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1997