Dispersive liquid–liquid microextraction combined with flame atomic absorption spectrometry for determination of cadmium in environmental, water and food samples
- 14 June 2011
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 3 (7) , 1652-1655
Abstract
A simple and reliable method for rapid and selective extraction and determination of trace levels of Cd2+ was developed by dispersive liquid–liquid microextraction (DLLME) coupled to flame atomic absorption spectrometry (FAAS) detection. The main factors affecting the DLLME, such as concentration of DPTH, pH, extraction and disperser solvent type and their volume, were optimized for the best extract efficiency. Under the optimum conditions, i.e., pH 5.4, [DPTH] = 6 × 10−3%, a preconcentration factor of 55 was reached. The lower limit of detection (LOD) obtained under the optimal conditions was 0.4 μg L−1. The precision for 14 replicate determinations at 30 and 100 μg L−1 of Cd was 2.7% and 1.9% relative standard deviation (R.S.D.), respectively. The calibration graph using the preconcentration method was linear from 5 to 100 μg L−1, with a correlation coefficient of 0.9898. The proposed method was successfully applied to the preconcentration and determination of cadmium in food, vegetation, and water samples and in a BCR-176 standard reference material.Keywords
This publication has 17 references indexed in Scilit:
- Ionic liquid-based ultrasound-assisted dispersive liquid–liquid microextraction combined with electrothermal atomic absorption spectrometry for a sensitive determination of cadmium in water samplesSpectrochimica Acta Part B: Atomic Spectroscopy, 2009
- Separation and Preconcentration by Dispersive Liquid–Liquid Microextraction Procedure: A ReviewChromatographia, 2009
- Miniaturized preconcentration methods based on liquid–liquid extraction and their application in inorganic ultratrace analysis and speciation: A reviewSpectrochimica Acta Part B: Atomic Spectroscopy, 2009
- Critical review on recent developments in solventless techniques for extraction of analytesAnalytical and Bioanalytical Chemistry, 2008
- Preconcentration Ultra Trace of Cd(II) in Water Samples Using Dispersive Liquid-Liquid Microextraction with Salen(N,N′-Bis(Salicylidene)-Ethylenediamine) and Determination Graphite Furnace Atomic Absorption SpectrometryJournal of the Chinese Chemical Society, 2008
- Review of procedures involving separation and preconcentration for the determination of cadmium using spectrometric techniquesJournal of Hazardous Materials, 2007
- Dispersive liquid–liquid microextraction combined with graphite furnace atomic absorption spectrometryAnalytica Chimica Acta, 2007
- Dispersive liquid–liquid microextraction combined with gas chromatography-flame photometric detectionJournal of Chromatography A, 2006
- Determination of organic compounds in water using dispersive liquid–liquid microextractionJournal of Chromatography A, 2006
- Development of an on-line solvent extraction system for electrothermal atomic absorption spectrometry utilizing a new gravitational phase separator. Determination of cadmium in natural waters and urine samplesJournal of Analytical Atomic Spectrometry, 2003