Does Use of a Jig Influence the Precision of Tibial Plateau Leveling Osteotomy Surgery?
- 24 April 2007
- journal article
- Published by Wiley in Veterinary Surgery
- Vol. 36 (3) , 228-233
Abstract
To compare the precision of tibial plateau leveling osteotomy (TPLO) surgery when performed with or without a jig. Cadaveric study. Cadaveric, adult greyhound hindlimbs (n=9 pair). TPLO (n=18) was performed on each limb pair; 1 with and 1 without use of a jig. Measurements taken from pre- and postsurgical radiographs were osteotomy position, tibial plateau angle (TPA), varus-valgus malalignment, and tibial torsion. The null hypothesis was that TPLO precision was not affected by use of a jig. Student's t-test was used to investigate differences in TPA, osteotomy location, and frequency and extent of iatrogenic limb malalignment; P<.05 was considered significant. There were no significant differences in postsurgical TPA, tibial crest thickness, varus-valgus malalignment, or tibial torsion between TPLOs performed with or without a jig. Osteotomy location was significantly more distal when a jig was used (P=.03). Jig use did not improve the precision of TPLO surgery. Performing TPLO without a jig should reduce surgery time, eliminate complications related to placement of the distal jig pin and allow unhindered positioning of the osteotomy.Keywords
This publication has 10 references indexed in Scilit:
- Comparison of Computed Tomographic and Standard Radiographic Determination of Tibial Torsion in the DogVeterinary Surgery, 2005
- The Effect of Tibial Plateau Leveling Osteotomy Position on Cranial Tibial Subluxation: An In Vitro StudyVeterinary Surgery, 2005
- Synthesis of Single‐Crystalline Silicon Nitride Nanobelts Via Catalyst‐Assisted Pyrolysis of a PolysilazaneJournal of the American Ceramic Society, 2005
- Influence of Limb Positioning and Measurement Method on the Magnitude of the Tibial Plateau AngleVeterinary Surgery, 2004
- Geometric analysis evaluating the effect of tibial plateau leveling osteotomy position on postoperative tibial plateau slopeVeterinary and Comparative Orthopaedics and Traumatology, 2004
- Observer variability of tibial plateau slope measurement in 40 dogs with cranial cruciate ligament‐deficient stifle jointsVeterinary Surgery, 2003
- In Vitro Effects of Osteotomy Angle and Osteotomy Reduction on Tibial Angulation and Rotation During the Tibial Plateau‐Leveling Osteotomy ProcedureVeterinary Surgery, 2003
- Complications with and owner assessment of the outcome of tibial plateau leveling osteotomy for treatment of cranial cruciate ligament rupture in dogs: 193 cases (1997–2001)Journal of the American Veterinary Medical Association, 2003
- Surgical and postoperative complications associated with tibial plateau leveling osteotomy in dogs with cranial cruciate ligament rupture: 397 cases (1998–2001)Journal of the American Veterinary Medical Association, 2003
- Intra- and interobserver measurement variability of tibial plateau slope from lateral radiographs in dogsJournal of the American Animal Hospital Association, 2001