Two experimental techniques have been used to quantify the atomic oxygen density in the case of hot air plasma generated by a microwave (MW) resonant cavity. The latter operates at a frequency of 2.45 GHz inside a cell of gas conditioning at a pressure of 600 mbar, an injected air flow of 12 L/min and an input MW power of 1 kW. The first technique is based on the standard two photon absorption laser induced fluorescence (TALIF) using xenon for calibration but applied for the first time in the present post discharge hot air plasma column having a temperature of about 4500 K near the axis of the nozzle. The second diagnostic technique is an actinometry method based on optical emission spectroscopy (OES). In this case, we compared the spectra intensities of a specific atomic oxygen line (844 nm) and the closest wavelength xenon line (823 nm). The two lines need to be collected under absolutely the same spectroscopic parameters. The xenon emission is due to the addition of a small proportion of xenon (1% Xe) of this chemically inert gas inside the air while a further small quantity of H2 (2%) is also added in the mixture in order to collect OH(A-X) and NH(A-X) spectra without noise. The latter molecular spectra are required to estimate gas and excitation temperatures. Optical emission spectroscopy measurements, at for instance the position z=12 mm on the axis plasma column that leads to a gas measured temperature equal to 3500 K, an excitation temperature of about 9500 K and an atomic oxygen density 2.09×1017±0.2×1017 cm−3. This is in very good agreement with the TALIF measurement, which is equal to 2.0×1017 cm−3.Keywords
This publication has 10 references indexed in Scilit:
- Measurements of Absolute Atomic Oxygen Density by Two-photon Absorption Laser-induced Fluorescence Spectroscopy in Hot Air Plasma Generated by Microwave Resonant CavityPhysical Science International Journal, 2014
- Optical emission spectroscopy for quantification of ultraviolet radiations and biocide active species in microwave argon plasma jet at atmospheric pressureSpectrochimica Acta Part B: Atomic Spectroscopy, 2013
- Atomic oxygen TALIF measurements in an atmospheric-pressure microwave plasma jet within situxenon calibrationPlasma Sources Science and Technology, 2013
- Atomic oxygen in a cold argon plasma jet: TALIF spectroscopy in ambient air with modelling and measurements of ambient species diffusionPlasma Sources Science and Technology, 2012
- Two-photon absorption laser-induced fluorescence of atomic oxygen in the afterglow of pulsed positive corona dischargeJournal of Applied Physics, 2009
- Quantitative determination of the O(P3) density via visible cavity-enhanced spectroscopyApplied Physics Letters, 2006
- Behaviour of atomic oxygen in a pulsed dielectric barrier discharge measured by laser-induced fluorescenceJournal of Physics D: Applied Physics, 2005
- Absolute atomic oxygen density measurements by two-photon absorption laser-induced fluorescence spectroscopy in an RF-excited atmospheric pressure plasma jetPlasma Sources Science and Technology, 2005
- Optical diagnostics of atmospheric pressure air plasmasPlasma Sources Science and Technology, 2003
- Investigation of a pulsed oxygen microwave plasma by time-resolved two-photon allowed laser-induced fluorescenceJournal of Physics D: Applied Physics, 2002