Direct aperture optimization of breast IMRT and the dosimetric impact of respiration motion
Authors:
- 2 October 2006
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 51 (20) , N357-N369
Abstract
We have studied the application of direct aperture optimization (DAO) as an inverse planning tool for breast IMRT. Additionally, we have analysed the impact of respiratory motion on the quality of the delivered dose distribution. From this analysis, we have developed guidelines for balancing the desire for a high-quality optimized plan with the need to create a plan that will not degrade significantly in the presence of respiratory motion. For a DAO optimized breast IMRT plan, the tangential fields incorporate a flash field to cover the range of respiratory motion. The inverse planning algorithm then optimizes the shapes and weights of additional segments that are delivered in combination with the open fields. IMRT plans were generated using DAO with the relative weights of the open segments varied from 0% to 95%. To assess the impact of breathing motion, the dose distribution for the optimized IMRT plan was recalculated with the isocentre sampled from a predefined distribution in a Monte Carlo convolution/superposition dose engine with the breast simulated as a rigid object. The motion amplitudes applied in this study ranged from 0.5 to 2.0 cm. For a range of weighting levels assigned to the open field, comparisons were made between the static plans and the plans recalculated with motion. For the static plans, we found that uniform dose distributions could be generated with relative weights for the open segments equal to and below 80% and unacceptable levels of underdosage were observed with the weights larger than 80%. When simulated breathing motion was incorporated into the dose calculation, we observed a loss in dose uniformity as the weight of the open field was decreased to below 65%. More quantitatively, for each 1% decrease in the weight, the per cent volume of the target covered by at least 95% of the prescribed dose decreased by approximately 0.10% and 0.16% for motion amplitudes equal to 1.5 cm and 2.0 cm, respectively. When taking into account the motion effects, the most uniform and conformal dose distributions were achieved when the open segment weights were in the range of 65-80%. Within this range, high-quality IMRT plans were produced for each case. The study demonstrates that DAO with tangential fields provides a robust and efficient technique for breast IMRT planning and delivery when the open segment weight is selected between 65% and 80%.Keywords
This publication has 24 references indexed in Scilit:
- Clinical implementation of intensity‐modulated tangential beam irradiation for breast cancerMedical Physics, 2004
- Impact of breathing motion on whole breast radiotherapy: a dosimetric analysis using active breathing controlInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2004
- Inverse planning for intensity-modulated arc therapy using direct aperture optimizationPhysics in Medicine & Biology, 2003
- Quantifying the effect of intrafraction motion during breast IMRT planning and dose deliveryMedical Physics, 2003
- Organ motion and its managementInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2001
- Intensity modulation to improve dose uniformity with tangential breast radiotherapy: Initial clinical experienceInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2000
- Motion adaptive x-ray therapy: a feasibility studyPhysics in Medicine & Biology, 2000
- Dosimetric analysis of intact breast irradiation in off-axis planesInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1997
- Respiration gated radiotherapy treatment: a technical studyPhysics in Medicine & Biology, 1996
- The effect of the number of computed tomographic slices on dose distributions and evaluation of treatment planning systems for radiation therapy of intact breastInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1994