Enhanced Neointima Formation and Attachment on the High-Porosity Inner Surface of Modified PTFE Vascular Grafts
Authors:
- 1 January 1995
- journal article
- research article
- Published by Taylor & Francis in Journal of Investigative Surgery
- Vol. 8 (4) , 235-242
Abstract
Highly porous PTFE arterial prostheses form endothelium more extensively than the low-porosity grafts in clinical use, but are subject to seroma formation. PTFE vascular grafts were modified to produce a highly porous inner layer (inner layer 60 or 90 microns, outer layer 20 microns). The effect of this modified, composite design on the histology of graft healing was investigated. Twenty-five modified and 25 control grafts, each 4 mm in diameter by 5 cm in length, were implanted into carotid and femoral arteries of dogs. No late seroma formation was observed. After 12 and 18 weeks, the neointima of the grafts was examined by light microscopy and scanning electron microscopy. At 2- and 4-mm distances from the proximal and distal anastomoses, intimal thickness of the control grafts was 238.7 and 96.1 microns, respectively; for the modified grafts it was 236.2 and 202.8 microns at 18 weeks. Thus, the neotinima of modified grafts was thicker than that of control grafts when measured at 4 mm from the anastomoses. Neointimal coverage was less extensive in the control grafts than in modified grafts (26.8 +/- 6.1% vs. 58.8 +/- 13.2%; p < .05). Smooth muscle cells were seen on light-microscopy to penetrate the highly porous inner layer; on scanning electron microscopy, the PTFE fibrils appeared to anchor the neointima of the modified graft. The results suggest that modified PTFE grafts with an inner surface of 60 or 90 microns internodal distance have enhanced formation and anchoring of neointima while remaining impervious to blood.Keywords
This publication has 8 references indexed in Scilit:
- Endothelial seeding of polytetrafluoroethylene femoral popliteal bypasses: The failure of low-density seeding to improve patencyJournal of Vascular Surgery, 1994
- In Vivo Study of a High-Porosity Polytetrafluoroethylene Graft: Endothelialization, Fluid Leakage, and the Effect of Fibrin Glue SealingJournal of Investigative Surgery, 1993
- Healing of polytetrafluoroethylene arterial grafts is influenced by graft porosityJournal of Vascular Surgery, 1990
- Improved Healing of Microvascular PTFE Prostheses by Induction of a Clot LayerPlastic and Reconstructive Surgery, 1989
- Neointima formation in expanded polytetrafluoroethylene vascular grafts with different fibril lengths following implantation in the rat aortaMicrosurgery, 1989
- Mechanisms of healing in synthetic graftsJournal of Vascular Surgery, 1987
- Expanded Polytetrafluoroethylene as a Microvascular GraftPlastic and Reconstructive Surgery, 1985
- A Biomechanical, Scanning Electron, and Light Microscopic EvaluationAnnals of Surgery, 1982