Abstract
The potential energy saving resulting from replacing motors operating in industry, prior to the enactment of the Energy Policy Act of 1992, with NEMAreg Premium motors have been discussed. A methodology for the inclusion of motor reliability in the repair/replace decisions has also been proposed. The data used for the work was obtained from a recently completed project under which the older motors operating in various industries around the country were removed from service and tested for efficiency under laboratory conditions. The displaced motors were replaced by new NEMA Premiumreg motors.Keywords
This publication has 6 references indexed in Scilit:
- A Construction, Performance and Reliability Comparison for Pre-EPAct, EPAct and Premium-Efficient Motors2006
- Energy efficient motors-myths vs. reality2002
- Energy Policy Act of 1992 review as it pertains to AC induction motors2002
- Reasons for using IEEE standard 841-1994 motors for the forest products industry2002
- An overview of how AC induction motor performance has been affected by the October 24, 1997 implementation of the Energy Policy Act of 1992IEEE Transactions on Industry Applications, 2000
- Reliability comparison between standard and energy efficient motorsIEEE Transactions on Industry Applications, 1997