First clinical data on artificial intelligence‐guided catheter ablation in long‐standing persistent atrial fibrillation
Open Access
- 10 January 2024
- journal article
- research article
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 35 (3) , 406-414
Abstract
Introduction: Despite advanced ablation strategies and major technological improvements, treatment of persistent atrial fibrillation (AF) remains challenging and the underlying pathophysiology is not fully understood. This study analyzed the multiple procedure outcome and safety of catheter ablation of spatiotemporal dispersions (DISPERS) detected by artificial intelligence (AI)‐guided software in patients with long‐standing persistent AF.Methods and Results: The Volta VX1 software was used for 50 consecutive patients undergoing catheter ablation for persistent AF. First, high‐density mapping (78% biatrial) with a multipolar mapping catheter was performed. In addition to pulmonary vein isolation (PVI), ablation of DISPERS was performed aiming at homogenizing, dissecting, isolating, or connecting DISPERS areas to nonconducting anatomical structures. Follow‐up contained regular visits at our outpatient clinic at 1, 3, 6, and 12 months including 7‐day Holter electrocardiograms. Patients were mainly suffering from long‐standing persistent AF (mean AF duration 50.30 ± 54.28 months). Following PVI, ablation of left atrial and right atrial DISPERS areas led to AF cycle length prolongation (mean of 162.0 ± 16.6 to 202.2 ± 21.6 ms after) and AF termination to atrial tachycardia (AT) or sinus rhythm (SR) in 12 patients (24%). No stroke or pericardial effusion occurred; major groin complications (pseudoaneurysm n = 1, atrioventricular fistula n = 1) were detected in two patients. After a blanking period of 6 weeks, recurrence of any atrial arrhythmia was documented in 26 patients (52%). The majority of patients presented with organized AT (n = 15) while AF was present in n = 9 patients and AT/AF was observed in n = 2 patients. Twenty‐two patients underwent reablation. During a mean follow‐up of 363.14 ± 187.42 days and after an average of 1.46 ± 0.68 procedures, 82% of patients remained in stable SR.Conclusion: DISPERS‐guided ablation using machine learning software (the Volta VX1 software) in addition to PVI in long‐standing persistent AF ablation resulted in high long‐term success rates regarding AF and AT elimination. Most arrhythmia recurrences were reentrant AT. After a total of 1.46 ± 0.68 procedures, freedom from AF/AT was 82%. Despite prolonged procedure times complication rates were low. Randomized studies are necessary to evaluate long‐term efficacy of dispersion‐guided ablation using AI.Keywords
This publication has 18 references indexed in Scilit:
- Low-voltage area substrate modification for atrial fibrillation ablation: a systematic review and meta-analysis of clinical trialsEP Europace, 2022
- AF Ablation Guided by Spatiotemporal Electrogram Dispersion Without Pulmonary Vein IsolationJACC, 2017
- Catheter ablation in patients with persistent atrial fibrillationEuropean Heart Journal, 2016
- Cryoballoon or Radiofrequency Ablation for Paroxysmal Atrial FibrillationThe New England journal of medicine, 2016
- Approaches to Catheter Ablation for Persistent Atrial FibrillationThe New England journal of medicine, 2015
- Five-Year Follow-Up After Catheter Ablation of Persistent Atrial Fibrillation Using the Stepwise Approach and Prognostic Factors for SuccessCirculation: Arrhythmia and Electrophysiology, 2015
- Catheter Ablation of Long-Standing Persistent Atrial FibrillationJACC, 2012
- Predictors of Atrial Fibrillation Recurrence After Radiofrequency Catheter Ablation: A Systematic ReviewJournal of Cardiovascular Electrophysiology, 2010
- Outcomes of long-standing persistent atrial fibrillation ablation: A systematic reviewHeart Rhythm, 2010
- Long‐Term Outcome of Atrial Fibrillation Ablation: Impact and Predictors of Very Late RecurrenceJournal of Cardiovascular Electrophysiology, 2010